DIS AO 6004 Kullanıcı Kılavuzu - Sayfa 11
Aksesuarlar DIS AO 6004 için çevrimiçi göz atın veya pdf Kullanıcı Kılavuzu indirin. DIS AO 6004 14 sayfaları. Audio output unit for dcs 6000
Danish Interpretation Systems
Typical schematics
Connect the AO 6004 to the DCS 6000 network
using Cat 5 cables. The Analogue Audio output
connectors are connected to either tape recorders
Using AO 6004 with IT 6108 IR-Transmitter
When using the AO 6004 with the IT 6108 Infrared
Transmitter, the audio output level on the AO 6004
has to be set to match the sensitivity on the
transmitter.
Using AO 6004 with DT 60xx Digital IR-Transmitter
When using the AO 6004 with the DT 60xx
Infrared Transmitter, the audio output level on the
AO 6004 has to be set to match the sensitivity on
the transmitter.
The correct level on each connected channel on the
AO 6004 is +3dB. This level is factory preset, but
for recording the interpreted channels or to IT6008
Infrared
interpreted channels wireless.
The correct level to be set on each connected
channel on the AO 6004 is –12db.
can as earlier mentioned be changed using SW
6000. Please refer to the section 'Pre-configured
settings' on page 8. The DT 60XX input level
settings should be set to –6dB.
Manual 01 18 04442
Transmitter(s)
for
User Manual
transmitting
the
11