General safety precautions (Continued)
- Air exhaust, water drainage and contamination control
- Exhaust sampling port
- Facility side interlock connection terminal (Special user
- Machine relocation/disposal
Since harmful substance may be generated depending on the
cutting work type and machining characteristics, air exhaust, water
drainage and contamination control/disposal must be properly
completed in compliance with applicable environmental protection
codes.
The machine requires an exhaust operation. When measuring the
exhaust for the machine to fulfill legal requirements, use the
sampling port, which is provided at the location indicated below.
(connection port: Rc (PT) 1/8 female)
specification)
To permit the facility side to provide air exhaust and water drainage
interlock, the machine is equipped with air exhaust and water
drainage reservoir tank interlock connection terminals.
When connecting these terminals to the facility side interlock
system, contact your nearest DISCO office.
In the case of relocation or disposal of the machine, the
presentation of detailed precautionary notes and the management
of new installation site data will be done by DISCO.
If you want to relocate or disposal the machine, contact your
nearest DISCO office or DISCO service office.
N O T I C E
[A]
View [A]
Duct
Sampling port
[Rc(PT)1/8 female]
A-3