PILOT VALVE SERVICING

To service the pilot valve first shut
off the compressed air supply, bleed
the pressure from the pump, and
disconnect the air supply line from
the pump.
Step #1: See PUMP ASSEMBLY
DRAWING.
Using a ½" wrench or socket,
remove the four capscrews (items
11) and four flat washers (items 38).
Remove the air inlet cap (item 8) and
air inlet gasket (item 20). The pilot
valve assembly (item 4) can now be
removed for inspection or service.
Step #2: Disassembly of the
pilot valve.
Remove the pilot valve spool
(item 4-E). Wipe clean, and inspect
for dirt, scratches or wear. Replace
the spool if necessary.
Remove the two retaining rings
(items 4-C) from each end of the
pilot valve body.
Remove the two pilot valve bush-
ings (items 4-B), five spacers (items
4-D), and six spool wipers (items
4-F) by pushing gently from other
end of the pilot valve body. Inspect
the wipers for cuts and/or wear.
Replace any wipers as necessary.
520-319-000 Air Operated Double Diaphragm Pump
Step #3: Re-assembly of the
pilot valve.
First install a retaining ring to one
end of the pilot valve. Install one
bushing making sure the step side
faces toward the wiper. Apply a light
coating of grease to the outside
diameter of each wiper. Next, gently
push in the wipers and spacers until
they are against the installed retain-
ing ring and bushing in the opposite
end of the pilot valve body. Install the
remaining bushing making sure the
step side faces the wiper. Install the
remaining retaining ring.
Apply a light coating of grease to
the inner diameter of each wiper.
Also apply a light coating of grease
to the outer diameter of the pilot
valve spool and gently push the
spool through each wiper.
Step #4: Inspect the actuator
plungers.
See ILLUSTRATION AT RIGHT.
The actuator plungers (items 31)
can be reached through the pilot
valve cavity in the intermediate
assembly (item 5).
Remove the plungers (item 30)
from the bushings (item 7) in each
end of the cavity. Inspect the installed
o-ring (items 27)for cuts and/or wear.
11/01
PILOT VALVE ASSEMBLY PARTS LIST
ITEM
PART NUMBER
4
B095-096-000
4-A
B095-095-551
4-B
B135-037-506
4-C
B675-057-115
4-D
B770-065-175
4-E
B775-041-506
4-F
B917-003-374
Replace the o-rings if necessary.
Apply a light coating of grease to
each o-ring and re-install the plung-
ers in to the bushings. Push the
plungers in as far as they will go.
To remove the bushings (item 7),
first remove the retaining rings
(item 32) by using a flat screwdriver.
NOTE: It is recommended that new
retaining rings be installed.
Step #5: Re-install the pilot valve
assembly into the intermediate
assembly.
Be careful to align the ends of the
stem between the plungers when
inserting the stem of the pilot valve
into the cavity of the intermediate.
Re-install the gasket (item 20), air
inlet cap (item 8), capscrews and
washers (items 11 and 38).
Connect the air supply to the
pump. The pump is now ready for
operation.
DESCRIPTION
QTY
Pilot Valve Assembly
Body, Pilot Valve
Bushing
Ring, Retaining
Spacer
Spool, Pilot
Wiper
IMPORTANT!
Read these instructions completely, before
installation and start-up. It is the
responsibility of the purchaser to retain
this manual for reference. Failure to
comply with the recommendations stated
in this manual will damage the pump,
.
and void factory warranty
ACTUATOR PLUNGER
SERVICING
7
27
31
5
Page 8
1
1
2
2
5
1
6
32