OPERATION MODES:
Model CV-634PR is equipped with 2 electronically
interlocked devices - the Proximity Reader and the
Piezoelectric Keypad.
It supports the following operation modes:
1. Prox + Pin. Present Prox card. The unit will read the
content and send it over the Data wires to the host.
Enter PIN code. The unit will send each digit over the
same Data wires to the host. The Keypad and the Prox
reader are interlocked so that when one is functioning
the other is inhibited until the data is transmitted.
2. Prox Only. The prox electronics is independently
communicating via Data wires.
Wiring
COLOR
RED
BLACK
GREEN
WHITE
BROWN
BLUE
VIOLET
ORANGE
GREY
Everswitch Proximity Reader Plus Keypad
Output formats: 26 bit Wiegand with programmable
Power Supply: 5 to 12 VDC
Power Consumption: Max 150 mA
Transmitter/Receiver frequency: 125Khz
Mounting: Universal (single gang box)
Environment: IP68 ; 100% relative humidity
Operating Temperature: - 20 to + 70ºC
Dimensions: 120 x 90 x 20mm (4.72" x 3.54" x .79")
Certifications: Complies with FCC Part 15
3. Keypad Only. The keypad electronics is independently
Verification
Apply power to the unit. During the first 5 seconds it is
possible to reprogram the Site code (see instructions on next
page). The unit will activate the buzzer and the Yellow LED 3
times. At the same time the RED or the Green LED will come
ON depending on the Central Computer setup.
Present a valid HID encrypted card at 5 cm (2") distance
maximum. The unit will activate the Buzzer and the Yellow
Led once.
Enter any combination of PIN code up to 65534. The
unit will activate the Buzzer and the Yellow Led with each
pressed key.
FUNCTION
Input Voltage
Ground
Data 0
Data 1
LED Input
CCTV output
Housing Ground
Buffered Input
Tamper Output
Installation Instructions
site code
Anti-tamper Optical protection
communicating via Data wires..
ELECTRICAL FUNCTION
5 to 12 VDC
Open collector 1Kohm pull-up to internal +5V
Open collector 1Kohm pull-up to internal +5V
No Voltage
Open collector 0,250 A activated with each
key for 30 sec
Open collector 0,100 A "Low" when light sensed
Model CV-634PR