CAMDEN CM-47-ADP1 Manuel

Kapı açma sistemi CAMDEN CM-47-ADP1 için çevrimiçi göz atın veya pdf Manuel indirin. CAMDEN CM-47-ADP1 2 sayfaları.

D o o r Ac t iv a ti o n D e v i c e s
CM-47-ADP1 Manual
INSTALLATION INSTRUCTIONS
THIS PACKAGE INCLUDES:
(1) Extension Ring
(1) Parts Kit
1. GENERAL DESCRIPTION
Camden Door Controls CM-47-ADP1 extension ring can be
mounted with the CM-47S ABS Round enclosure and with the
Camden CM-40 series 'all active' heavy-duty, ADA compliant door
activation switches. These switches are UL/CSA approved and
optional Weatherproof, watertight coating are available.
2. SPECIFICATIONS
CM-69-ADP1:
Dimensions
5'' DIA x 1-1/4''D
(167mm x 31mm)
4. CM-47SER SERIES FRONT AND SIDE VIEW
5''
[128mm]
3. INSTALLATION
ACTIVE SWITCH INSTALLATION:
Firmly mount the Black polymer (ABS) box (Sold Separately)
against a surface or a wall. Place the extension ring over the
round enclosure. Align the crescents with the middle standoff
of the round box to help keep the ring in place. Screw the two
6-32 x 1-1/2'' screws through the ring and into the round box.
Don't screw all the way, leave about 1/4" of room for the switch
to be mounted. To place the switch onto the ring, start with the
bottom, slide the groove at the bottom of the backplate over the
screw then put the top screw through the cut-out at the top of the
backplate and slide the switch down. Take a screwdriver or the
supplied hex key and tighten the socket head screws, securing the
switch in place.
1 1 4 ''
[31mm]
Page 1 of 2