NOTE: Wait until the fire pit is cool before
covering.
During periods of extended inactivity or when transporting
•
Turn the control knob OFF.
•
Disconnect the LP source, and move it to a secure, well-ventilated location outdoors.
•
Store the fire pit upright in an area sheltered from direct contact with inclement weather (such as rain,
sleet, hail, snow, dust and debris).
•
If desired, cover fire pit to protect exterior surfaces and to help prevent build-up in air passages.
WARNING: Never leave LP cylinder exposed
to direct sunlight or excessive heat. Wait until
the fire pit is cool before covering.
CAUTION: Always the allow fire pit to cool
before attempting service.
Service
Only a qualified service person should repair gas passages and associated components.
Troubleshooting
PROBLEM
The burner will not light.
The burner flame is too low.
Carbon build-up and/or thick black
smoke is present.
POSSIBLE CAUSE
□
The propane cylinder is
frosted over.
□
An opening is blocked.
□
The control knob is not in the
ON position.
□
There may be too much lava
rock covering the burner bowl
or small pieces may be
blocking the burner holes.
□
The gas pressure is low.
□
The outdoor temperature is
less than 40°F, and the tank
is less than ¼ full.
□
There is dirt or film on the
reflector and burner screen.
□
The burner is blocked.
12
CORRECTIVE ACTION
□
Wait until the propane
cylinder warms up and
becomes unfrosted.
□
Clear the blockage.
□
Turn the control knob to ON.
□
Remove a portion of the lava
rock.
□
Turn the cylinder valve off
and replace the cylinder.
□
Use a full propane cylinder.
□
Check the burner and
openings for blockage.
□
Clean the reflector and
burner screen.
□
Remove any blockage, and
clean the burner inside and
outside.