Figure 64 presents two calibration models – part X. The first one (at the top) has incorrect offset values along the X
axis, while the second one (at the bottom) has correctly calibrated offset values along the X axis (fig. 64). With
correctly calibrated offsets on the middle line (point 0.00), the model material coincides with the support material
both in the X axis and in the Y axis (Fig. 64, bottom model).
3DGence DOUBLE P255 - maintenance activities | version 07.2021
Fig. 62 Calibration model of offset along X axis
Fig. 63 Calibration model of offset along Y axis