diversey CO350.5X Manuel - Sayfa 5
Temizlik Ekipmanları diversey CO350.5X için çevrimiçi göz atın veya pdf Manuel indirin. diversey CO350.5X 11 sayfaları.
Preparation for operation
Batteries
Caution:
Only maintenence-free gel traction block batteries may be used!
Please follow the instructions of use for your battery charger!
Safety measures when working with batteries:
• Protective goggles must be worn when working on the
batteries.
• Do not subject batteries to an open flame or heat as there is a
danger of explosion from the electolytic gas present in the
cells!
• No smoking!
• Danger of chemical burns!
Caution:
The battery must always be clean and dry. Do not place any
metallic objects on the battery.
The integrated charging unit is only suitable for maintenance-free
gel traction block batteries.
Battery connection diagram
Caution:
Batteries may only be installed or dismounted by customer
service personnel or specialists approved by Diversey who are
aware of all the safety regulations that apply here!
50A
Charger
BMS
2
BM
SM
DP
DV
Dashboard
6
5
4
3
2
1
Control
Charging procedure (traction block batteries with integrated charging
unit)
• Stand the machine on the parking support
before starting the charging procedure.
• Disconnect the battery from the machine using the battery disconnection
socket.
• Plug the power supply cord into the mains socket.
• The yellow indicator lights up permanently until
approx. 90% of the battery capacity has been
reached. After that, the indicator blinks until the
battery is fully charged.
• When the charging process is complete, the
green indicator lights up.
In order to protect the battery, the charging sequence is not
started after a short period of use of less than approx.15 minutes,
and the green lamp lights up immediately.
In this case, the battery is charged to more than 75%.
• Leave the power supply cord connected to the mains until you use the
machine again. The on-board charger unit automatically monitors and
charges the batteries. The energy consumption in the mode is limited to a
few milliwatts.
• If a fault occurs during the charging process as the result of a defect in the
charging unit, an interruption of a cable or a defective battery cell, the red
indicator will light up.
After completing the charging and with immediate use:
• Unplug the connection to the mains socket.
• Connect the battery to the machine with the battery disconnection socket.
Charging procedure (traction block batteries with external charging unit)
• Check that the machine is switched off.
• Disconnect the battery from the machine using the battery disconnection
socket.
• Connect the battery disconnection socket to the external battery charging
unit (pay attention to the voltage from the mains supply socket).
Caution:
Follow the instructions of use for your battery charger!
Attaching tools
• Switch the machine off.
Check:
• that the brushes are not below the red marking and that the bristle length is
no less than 1 cm.
Working with worn out, damaged and or wrong tools, could result
in possible damage to floors or their protective layers.
• Place the machine on the parking support.
• Remove the brush holder (2) by screwing off the
1
triangular handle (1).
2
• Insert the brush into the brush housing.
• You can push the brush upwards with your right
hand so that it will be taken up by the centring
hexagon in the brush housing.
45