7.0 Troubleshooting and correction
You have chosen the best quality and therefore deserve the best service. To avoid unnecessary disap-
pointments, you should check the following before contacting the nearest ALTO service organisation:
Fault
Machine will not start
Machine stops shortly
after the start
Fuses blow
Pressure fluctuating
and pulsating
Pressure varies from
max. to min.
(in suction mode)
No working pressure
Should other malfunctions occur than those mentioned above, please contact the nearest ALTO service
organisation.
Customer services (UK only): ALTO Cleaning Systems Ltd.
Cause
A fuse has blown
Power/plug not connected
Defective extension cable
Defective socket
Extension cables not cor-
rectly dimensioned
Wrong mains voltage
Water supply too low
Water filter clogged up
Nozzle partly blocked
High pressure hoses too
long
Suction height too high or
water too hot
Nozzle clogged up
No inlet water
Hoses/spray lance frozen
up
Gilwilly Industrial Estate
Penrith, Cumbria CA11 9BN
Correction
Change the fuse
Connect power/plug
Try without extension cable
Try another socket
Remove extension cable or use correct
cable dimension (see sec. 2.1).
Wait 1 minute and try to restart machine.
Check that the mains voltage corresponds
to the data on the model tag (see sec. 1.1).
Change to an installation corresponding
to the ampere consumption of the machine
at a minimum.
Dismount water hose and check the
water volume (min. 15 l/min.) NB: Avoid
long thin hoses (min. 3/4").
Clean the filter (see sec. 6.0).
Clean the nozzle (see sec. 6.1).
Dismount high pressure extension hoses
and retry. Extension hose max. 50m.
NB: Avoid long extension hoses with
many couplings.
Read section. 5.0
Clean the nozzle (see sec. 6.1)
Check inlet water
Let them thaw out