The positions and functions are listed here:-
ID set to 9
Group set to 0
1
2
3
4
5 to 9 not yet used.
ID set to 0
Group
0 to 9 not yet used.
Note that the head must be connected when powering up with the switches set as above.
The action only has to be carried out once as the head will remember the settings when
they are applied.
After switching on there will be a delay of about 60 seconds as the head may be in
'initialise' mode. When the new settings are complete the data/cue light will start flashing. At
this point remove power from the interface box and move the ID and Group switches back
to the required positions before powering up again.
Appendix 'E' – Connector Wiring.
XLR4 Power connector:-
1. 0v
2. NC
3. NC
4. +9 to +36v DC
XLR3 Audio Data connector:-
1. 0v (An earth connection here is not essential as the data is transformer balanced in
the interface box)
2. Balanced audio signal
3. Balanced audio signal (Note the polarity of the audio is not critical)
9w 'D' connector:-
1. +5v @ 100ma is available here
2. RS232 RX (Note the Rx baud rate is selectable on the front panel DIP switches)
3. RS232 TX. (The output baud rate is set at 38,400)
4. NC
Q3
Operation Manual V3.1
Disable all return data from head to Interface Box.
Enable VR data in D1 format.
Enable VR data in 'Raw' format.
Mag sensors OFF. (Head will not initialise but should keep previous
settings for tilt endstops and preset positions).
Mag sensors ON. (Head will initialise and move to preset 18).