Setting time:
< 3.5 ms
External resistance:
R
ext
H = Power supply
I
A
5.3 Accuracy
Reference value:
Measuring range
Basic accuracy:
Limit of error ≤ 0.5 % for ranges 0...≤ 150°
Limit of error ≤ 1.5 % for ranges from 0...> 150 to
0...270°
Reproducibility:
< 0.2 %
Infl uence of temperature
(-40...+70 °C)
± 0.2 % / 10 K
[-40...+158 °F]:
5.4 Installation Data
Material:
Housing: Metal (aluminium), Surface chromated
Alodine 400
Mounting position:
Any
Admissible static
loading of shaft:
Sense
radial max.
axial max.
5.5 Regulations
Spurious radiation:
En 61000-6-3
Immunity:
EN 61000-6-2
Test voltage:
500 Veff, 50 Hz, 1 min.
all electrical connections against housing
Common-mode voltage:
100 V, 50 Hz
Housing protection:
IP 50 acc. to EN 60529
5.6 Environmental conditions
Climatic rating:
Standard version
Temperature – 25 to + 70 °C [-13...158 °F]
Annual mean relative humidity ≤ 90 %
or
Version with improved climatic rating
Temperature – 40 to + 70 °C [-40...158 °F]
Annual mean relative humidity ≤ 95 %
Ex version
Temperature – 40 to + 55 °C [-40...131° F] at T6
resp. – 40 to + 70 °C [-40...158 °F] at T5
resp. – 40 to + 75 °C [-40...167 °F] at T4
Altitude:
2000 m max.
Transportation and
storage temperature:
– 40 to 80 °C [-40...176 °F]
Vibration resistance:
5 g per 2h in 3 directions
Shock resistance:
3x50 g per 10 splicing in all directions
5.7 Operation in potentially explosive environments:
Gas explosion
prevention:
Labeling:
Conform to standard:
Type of protection:
Temperature class:
Group according to
EN 60079-0:2012:
• The operation in other explosive atmospheres is not permissible.
• It is not permissible to make any alteration to equipment that is used in poten-
tially explosive environments.
Devices with explosion prevention must be operated in accor-
dance with the stipulations of the operating instructions. The rele-
vant laws, regulations and standards for the planned application
must be observed.
2
H [V] – 12 V
max. [kΩ] =
I
[mA]
A
= Output signal end value
Drive shafts dia.
2 mm
6 mm resp. 1/4"
16 N
25 N
130 N
Ex ia IIC T6 Gb
ATEX:
EN 60079-0:2012
EN 60079-11:2012
IECEx:
IEC 60079-0:2011
IEC 60079-11:2011-06
ia
T6
II
5.8 Dimensional drawing
48
120°
Fig. 1. KINAX 3W2 with standard drive shaft at front only,
Ø 2 mm [0.078"] , length 6 mm [0.236"] .
48
120°
Fig. 2. KINAX 3W2 with special drive shaft at front and at rear.
At front: Ø 2 mm [0.078"] , length 12 mm [0.472"] . At rear: Ø 2 mm [0.078"] ,
83 N
length 6 mm [0.236"] .
48
120°
Fig. 3. KINAX 3W2 with special drive shaft at front only,
∅ 6 mm [0.236"] , length 12 mm [0.472"] .
48
120°
Fig. 4. KINAX 3W2 with special drive shaft at front and at rear.
At front: ∅ 6 mm [0.236"] , length 12 mm [0.472"] . At rear: ∅ 2 mm [0.078"] ,
length 6 mm [0.236"] .
48
120°
Fig. 5. KINAX 3W2 with special drive shaft at front only,
∅ 1/4", length 12 mm [0.472"] .
48
120°
Fig. 6. KINAX 3W2 with special drive shaft at front and at rear.
At front: ∅ 1/4", length 12 mm [0.472"] . At rear: ∅ 2 mm [0.078"] ,
length 6 mm [0.236"] .
1
1
1
6
M3
4.5 low
26.1
7
1
1
12
1
M3
4.5 low
6
26.1
7
1
1
12
1
M3
4.5 low
7
26.1
1
1
12
1
M3
4.5 low
6
Ø2
Ø6 g6
26.1
7
1
1
12
1
M3
4.5 low
Ø1/4˝
(6.35 g6)
7
26.1
1
1
12
1
M3
4.5 low
6
Ø2
Ø1/4˝
(6.35 g6)
7
26.1
– 0.008
Ø 2
– 0.014
– 0.008
Ø 2
– 0.014
– 0.004
Ø6 g6
– 0.012
– 0.004
– 0.012
–0.005
–0.014
– 0.005
– 0.014