I/O Sistemleri esera automation Auto-E-Connect 11230 için çevrimiçi göz atın veya pdf Kullanıcı Kılavuzu indirin. esera automation Auto-E-Connect 11230 6 sayfaları. 4-fold analog input insulated for 1-wire bus

Art. No. 11230
14
Integration in FHEM
For the integration into the open source automation software FHEM we provide a software module for easy
integration of the 4-fold analog input into FHEM via 1-Wire Controller / 1-Wire Gateway. This eliminates the need
for evaluation scripts.
Details can be found on the ESERA website under "Compatible Controls / Central/FHEM Integration".
https://www.esera.de/kompatible-steuerungen-zentralen/fhem-integration/
15
Operating conditions
The module may only be operated at the specified voltages and ambient conditions. The device can be
operated in any position. The device is intended for use in dry and dust-free rooms. If condensation is
formed, allow at least 2 hours for the unit to acclimatize.
Do not operate the module in an environment in which flammable gases, vapors or dusts are present or
could be present.
16
Assembly
The module may only be operated at the voltages and ambient conditions specified for it. The device is
intended for mounting inside a switch cabinet as a stationary device.
17
Disposal note
Do not dispose of the device within the household waste!
According to the directive concerning old electrical and electronic appliances,
electronic devices must be disposed of via the collecting points for old electronic
appliances!
18
Safety instructions
When using products that come into contact with electrical voltage, the valid VDE regulations must be observed,
especially VDE 0100, VDE 0550/0551, VDE 0700, VDE 0711 and VDE 0860
All final or wiring work must be carried out with the power turned off.
Before opening the device, always unplug or make sure that the unit is disconnected from the mains.
Components, modules or devices may only be put into service if they are mounted in a contact proof housing.
During installation they must not have power applied.
Tools may only be used on devices, components or assemblies when it is certain that the devices are
disconnected from the power supply and electrical charges stored in the components inside the device have
been discharged.
Live cables or wires to which the device or an assembly is connected, must always be tested for insulation faults
or breaks.
If an error is detected in the supply line, the device must be immediately taken out of operation until the faulty
cable has been replaced.
When using components or modules it is absolutely necessary to comply with the requirements set out in the
accompanying description specifications for electrical quantities.
If the available description is not clear to the non-commercial end-user what the applicable electrical
characteristics for a part or assembly are, how to connect an external circuit, which external components or
additional devices can be connected or which values these external components may have, a qualified
electrician must be consulted.
It must be examined generally before the commissioning of a device, whether this device or module is basically
suitable for the application in which it is to be used.
In case of doubt, consultation with experts or the manufacturer of the components used is absolutely necessary.
For operational and connection errors outside of our control, we assume no liability of any kind for any resulting
damage.
Kits should be returned without their housing when not functional with an exact error description and the
accompanying instructions. Without an error description it is not possible to repair. For time-consuming assembly
or disassembly of cases charges will be invoiced.
During installation and handling of components which later have mains potential on their parts, the relevant VDE
regulations must be observed.
Devices that are to be operated at a voltage greater than 35 VDC / 12mA, may only be connected by a qualified
electrician and put into operation.
Commissioning may only be realized if the circuit is built into a contact proof housing.
All rights reserved. Reproduction as well as electronic duplication of this user guide, complete or in part, requires the written consent of
ESERA GmbH. Errors and technical modification subject to change. ESERA GmbH, ESERA-Automation 2020
www.esera.de
11230 V2.0 R1.0 Manual