7. A dialog box confirming the successful update is displayed when the update is complete. If any I/Ports
did not update successfully, a dialog box containing the names of these I/Port is displayed. Write these
names down and deploy the update to these I/Ports individually.
8. If an I/Port cannot be successfully updated via Grid Center, attempt to update the I/Port locally (using
the first procedure) before contacting ClearCube technical support.
Note: Grid Center 4.0 requires TCP ports 3389, 6500, and 9000 to be open for these files to be transferred
correctly. Grid Center 4.1 requires TCP ports 137 and 9000, and UDP port 4001 to be open for these files
to be transferred correctly.
For more information, please contact ClearCube technical support.
support.clearcube.com
(866) 652-3400
+1 (512) 652-3400
NOTE 1:
These updates require the use of the Microsoft
the 1715 image, you may have to take additional steps.
To determine which version of the I8800 I/Port image you are using, click the Start button and then click
the About button. The image number is displayed next to the version label.
Example:
9235.1715.256
If you have I/Ports with an image version higher than 1715, you are not affected by this issue.
Installing the Grid Center Client on an I/Port installs the
using an I/Port with the 1715 image and have the CCT Grid Center Client installed, then you are not
affected by this issue.
If you do NOT have the Grid Center Client installed on your I/Port and you ARE using the 1715 image,
then you need to install the
To install the
command file on your I/Port, do the following:
xcopy.exe
1. Locate the
command file on any Microsoft Windows XP system. This command file is
xcopy.exe
located in the
\Windows\System32
2. Copy this command file to a USB Mass Storage Device (MSD) such as a USB Floppy or USB memory
stick.
3. Log into your I/Port as Administrator.
4. Copy the
command to the
xcopy.exe
5. Click Start, then click Logoff.
You can now apply the updates to the I/Port.
ClearCube Technology 8834 Capital of Texas Hwy N Suite 140 Austin, Texas 78759 voice 512 652 3500 www.clearcube.com
Email address for ClearCube Technical Support
ClearCube Support Website
Direct line in the US
Direct line from outside the US
xcopy.exe
command file.
xcopy.exe
directory.
C:\Windows\System32
ClearCube Public Technical Document
Document Code: TB0096JS
command file. If you are updating an I/Port with
command file on your I/Port. If you are
xcopy.exe
directory.