Dixon Bayco FT310 Bakım ve Kullanım Talimatları - Sayfa 3
Aksesuarlar Dixon Bayco FT310 için çevrimiçi göz atın veya pdf Bakım ve Kullanım Talimatları indirin. Dixon Bayco FT310 6 sayfaları. Trailer mounted individual sockets
FT300 Series Trailer Mounted Individual Sockets
Wiring Instructions
When wiring the sockets to an onboard monitor it is highly recommended
using FloTech FT401 jacketed 5-conductor cable when wiring a new
system. FloTech cable is designed to be oil, UV, and abrasion resistant.
We incorporate a noble tin plated stranded copper wire which resists
corrosion. These features will provide years of reliable service.
1. After all sensors are mounted in each compartment, align the conduit
openings so they face the roll over rail.
2. Thread in cable glands and pull a length of cable through the conduit
openings between each sensor.
3. Cut to length leaving approximately 8" extra length exiting the top of
each probe holder.
4. All socket cables must enter or leave through one of the ½" NPT
openings. Use FloTech FT402 ½" NPT cable glands to ensure a water
tight seal. Unused conduit openings must have a ½ NPT pipe plug
installed. Use pipe dope on all ½" NPT threads to ensure a water tight
seal.
5. Wire the sockets according to diagram 2 below. Double check your
wiring connection when complete. It is highly recommended to use a
small amount of Silicone RTV sealant in each crimp connection. Fill the
FloTech butt end crimps with Silicone RTV sealant prior to inserting the
wires then crimp. This will provide a watertight and vibration resistant
connection.
When wiring is complete, replace each sensor cap and O-ring.
Do not pinch a sensor wire when installing the cap.
FT300 Series
REV JANUARY 2011
3