ARTHUR HOLM DynamicCourtesyBox Kullanıcı Kılavuzu - Sayfa 13
İç Mekan Mobilyaları ARTHUR HOLM DynamicCourtesyBox için çevrimiçi göz atın veya pdf Kullanıcı Kılavuzu indirin. ARTHUR HOLM DynamicCourtesyBox 20 sayfaları.
AHNET PROTOCOL
Communications protocol
COMMUNICATION
CONNECTION
WIRING
Wiring Diagram
1. Data TX +
2. Data TX –
3. Data RX +
4. NC
5. NC
6 .Data RX
7. NC
8. NC
Connection
PINS 1 & 2
The units respond
PINS 3 & 6
The units receive instructions
Protocol to control the unit by addressable RS422 bus.
You can connect up to 30 monitors on the same RS422 bus.
You can use a AH Interface Ethernet, to control the RS422 bus.
The units should have a set address and the address must start by 1.
Maximum cable length between ends, 500 m/1640 ft.
AHnet protocol
Using 5 bytes communication:
BYTE 0
BYTE 1
BYTE 2
BYTE 3
BYTE 4
RS422
RJ45
CAT-5
START BYTE
ADDRESS BYTE
COMMAND BYTE
VALUE 1
VALUE 2
Speed and configuration
BAUD RATE
DATA BITS
PARITY
STOP BITS
RJ-45
38400
8
NONE
1
13