CONNECTING PRINCIPLE WITH PILOT WIRE:
Your appliance is equipped with a pilot wire for connection to a pilot wire program-
ming base unit (not supplied with the appliance).
N (blue or grey)
L (brown)
Pilot wire (black)
NOTE:
Your appliance is equipped with an integrated electronic control system
so we cannot accept any liability should the appliance be used with pilot
wire programming base units that function by disconnecting the supply
voltage (refer to the instructions supplied with your control unit).
CONNECTING PRINCIPLE WITHOUT PILOT WIRE:
If the pilot wire is not connected, it must be insulated for safety reasons. Under
no circumstances must it be connected to earth.
N (blue or grey)
L (brown)
Pilot wire (black)
28
Neutral
Live
Pilot wire (base unit)
Neutral
Live
40005972
3. Using your dual-energy towel
radiator
IMPORTANT This appliance has been designed to be
used either in central heating mode or electric mode.
Each application requires special, detailed procedures
to be followed. Inappropriate use may damage the resis-
tance as a result of excessive fluid temperatures, parti-
cularly in the event of simultaneous use in electric and
central heating modes.
Any inappropriate use will render the contractual gua-
rantee null and void.
3.1 Use as central heating
Ensure that the control unit is off.
The supply valve must be open to let water from the central heating system
circulate.
3.2 Use as electrical heating
A. When using the dual-energy, towel-drying radiator in "electric mode", close
the supply valve only and NEVER CLOSE THE HEATING UNIT'S OUTLET since this
enables the fluid to expand towards the installation.
CAUTION
Closing it may cause excessive pressure to build up with consequential
damage to the heating unit.
B. Ensure that the appliance is sufficiently full by opening the bleed tap at the
top. Close it again if there is a steady flow of water. A sponge and small container
should be used for this operation.
If the pressure is inadequate for bleeding the heating unit:
• fill the central heating system with water up to the level indicated on your
gauge,
• contact your heating specialist,
• inform the operating company (where heating is collective).