CALIBRATION
Step 1. Use a 0.050" allen wrench to
loosen the set screw on the black knob
to remove the micrometer dial.
Step 4. Align the post on the bottom of the dial to the bottom hole on the micrometer
face as shown.
Step 6. Load correct die set into crimper for your test crimp. Put the proper setting into the micrometer then perform test crimp.
If crimp is still tight or loose follow steps 7 thru 10.
Step 7. If the crimp diameter is too tight by 0.004" spin the dial to 2 at the top and 00 at the bottom. Loosen the set screw on
the black knob, spin the dial to 1 at the top and 90 at the bottom and then retighten the set screw. Return the dial to your setting
and crimp another fitting.
Step 8. If the crimp diameter is too tight by 0.008" spin the dial to 2 at the top and 00 at the bottom. Loosen the set screw on
the black knob, spin the dial to 1 at the top and 80 at the bottom and then retighten the set screw. Return the dial to your setting
and crimp another fitting.
Step 9. If the crimp diameter is too loose by 0.004" spin the dial to 2 at the top and 00 at the bottom. Loosen the set screw on
the black knob, spin the dial to 2 at the top and 10 at the bottom and then retighten the set screw. Return the dial to your setting
and crimp another fitting.
Step 10. If the crimp diameter is too loosen by 0.008" spin the dial to 2 at the top and 00 at the bottom. Loosen the set screw
on the black knob, spin the dial to 2 at the top and 20 at the bottom and then retighten the set screw. Return the dial to your
setting and crimp another fitting.
Step 11. If your crimp it outside of these numbers, or you need additional assistance please call technical service at
219.462.6128.
10
Innovating SMART Hose Assembly Solutions Since 1979
Step 2. Rotate the micrometer shaft
counter clockwise until the shaft stops
spinning.
Step 3. Align the numbers on the dial so
that 20 is shown in the black and 75 is
shown in the silver.
Step 5. Make sure the dial is sitting flat
against the micrometer then retighten
the set screw on the black knob.
20
75