Sensor Functions
Alarm LED can be switched either "ON" or "OFF".
Pulse Count can be switched to either "2" or "4" pulse
mode depending on the environmental conditions
of the installation.
Pulse Count
• Select "2" for normal applications.
• Select "4" for use in areas where there may be
movement by small animals or other objects,
such as fax machines or curtains.
Walk Test Jumper puts sensor in Walk Test Mode when
connected or Normal Mode when not connected. The
LED will light up and an alarm will be sent whenever
motion is detected if the unit is in Walk Test Mode. In
Normal Mode, the unit will only send an alarm every 2
minutes, and the LED will only light up if the "LED ON"
jumper is connected.
Mounting and Jumper Locations
Detection Range
LED
Pulse Count