QUICKSTART "BASIC" GUIDELINES FOR MODEL 115 VAC 6004 - DIP-SWITCH AND WIRING REFERENCE
Model 115 VAC 6004 is intended for installation only on swing gates used for vehicles.
Pedestrians must be supplied with a separate access opening. For safety and installation instructions, please refer to the
6004 Actuator Arm and Control Box Mounting manual and the 115 VAC Control Box Wiring/Owner's manual.
SW 1 DIP-Switches
Switch Function
Setting
Opening Direction of PRIMARY Operator
Opens counter-clockwise.
1
Left-Side
OFF setting.
Opens clockwise.
Opening
Same opening directions as illustrated above for the primary operator type.
2
Direction of
• Switch 2 will be the OPPOSITE setting as switch 1.
SECONDARY
Note: SW1, switch 7 MUST also be ON when using a secondary operator.
Operator
Exit Loop Port
OFF
Terminal #4 is output from plug-in exit loop detector installed in EXIT loop port.
3
Output
SW 1
Open Input
ON (normal) Terminal #4 is normal open command.
OFF
Auto-close timer is OFF. Manual input required to close gate.
Auto-Close
4
Timer
ON
Auto-close timer is ON. Adjustable from 1-23 seconds.
OFF (normal)
Terminal #8 is a standard Reverse input.
Reverse
5
Not Used
ON
On setting is NOT used.
Both operators start at the same time.
OFF
Overlapping
6
Gates
ON
Secondary operator opens 1-2 seconds before primary operator. Vice-versa when closing.
Single
Switch must be OFF for single operator.
OFF
7
Dual
Switch must be ON when (dual) operators are used.
ON
8
Input Power
OFF
Switch MUST be in the OFF position.
SW 2 DIP-Switches
Switch
Function
Setting
Relay activates when gate is fully open.
1-OFF
2-OFF
Relay activates when gate is not closed.
Relay
1-OFF
2-ON
1 and 2
Operation
Relay activates when gate is opening and open. Shadow loop setting if used.
1-ON
2-OFF
Relay activates when gate is opening and closing.
1-ON
2-ON
Maglock Used
ON
1 second delay to disengage maglock.
3
SW 2
OFF
Leave in the OFF position if a maglock is NOT used.
No Maglock
4
Spare
OFF
Leave in the OFF position.
Description
ON setting.
OFF setting.
Opens clockwise.
Right-Side
ON setting.
Opens counter-clockwise.
Note: After a DIP-switch
setting is changed, press the
reset button for new settings
to take effect.
Description
Main Terminal
1
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Reversing input on
Terminal #8
functions ONLY
while the gate is at
the FULL OPEN
position or during the CLOSING cycle. It
MUST NOT be used as an input for a
secondary entrapment protection device
during the OPENING gate cycle. Refer to
3-Wire
Secondary Entrapment Protection Wiring
RF Receiver
in the Wiring/Owner's manual.
Do not power any control
devices from the circuit
board other than low
voltage devices.
Power
Relay
Relay Com
4-Wire
Power Com
RF Receiver
Deluxe
115 VAC
Control
Box
Three 115 VAC Convenience Outlets
Power safety and opening devices
that require 115 VAC power.
Inglewood, California 90301
Com
N.C.
Note: Circuit board provides
24 VDC to power maglock.
Contact rating is 1 amp
maximum at 24 Volts.
Safety Opening Device
(Dry contact)
Com
N.O.
Connect optional control devices to
the main terminal. Use 18 AWG wire
for all low voltage wiring, maximum
Com
distance 3000 feet. Use a low voltage
surge suppressor, (DoorKing P/N
N.O.
1878-010) if low voltage wire runs
Keypad
exceed 1000 feet. All control device
(Dry contact)
inputs to the terminal must be
NORMALLY OPEN.
Com
N.O.
Controls must be far
enough from the gate so
Key Switch
that the user is prevented
(Dry contact)
from coming in contact
with the gate while
operating the controls.
Com
N.O.
Telephone Entry
Note: Must use a
separate power source.
120 Glasgow Avenue
U.S.A.
Magnetic Lock
SW 2
Switch 3 ON
SW 1
Switch 3
MUST be
ON.