6. Ignore Facility Code
1. Turn the Programming Selector to Position 6.
2. Press and hold Program Button until the Program LED flashes ONCE and receiver will BEEP once.
3. Receiver LED will then give a long flash and beep.
4. This indicates receiver will ignore the facility code before outputting the transmitter code.
START
7. Learn Master Transmitters (Up to 4)
1. Turn the Programming Selector to Position 7.
2. Press and hold Program Button until the Program LED flashes ONCE and receiver will BEEP once. Receiver is now in "Learn Mode" and will
flash and beep every second for 10 seconds.
3. Press the button on the master transmitter to be "Learned" within 10 seconds. Receiver will reset 10 second timer after each master
transmitter button has been pressed.
Master Transmitters Note:
The receiver only allows 4 master transmitters to be saved in the memory.
Press and
2 Sec.
Hold Program
Button
One Quick Flash
START
and Beep
4. Press other master transmitter buttons to be learned, each within a 10 second time period.
Less than 10 Seconds Idle Time
1 Sec.
1
1
1
Activate another
master Transmitter
Beep
5. After all desired master transmitters have been learned by the receiver (up to 4 total), wait for the receiver to time-out.
8. LOW -Power Mode
If you need to change the receiver from normal-power to LOW-Power mode, follow the steps below. LOW-power mode is used in DoorKing solar
gate operator applications.
1. Turn the Programming Selector to Position 8.
2. Press and hold Program Button until the Program LED flashes ONCE and receiver will BEEP once.
3. Receiver LED will then give a long flash and beep.
4. This indicates receiver will be put into LOW-Power mode which consumes LESS power than NORMAL-Power mode.
START
9. NORMAL -Power Mode (Factory Set)
The receiver comes from the factory already set in NORMAL-Power mode. If you need to change the receiver from LOW-Power to NORMAL-Power
mode, follow the steps below.
1. Turn the Programming Selector to Position 9.
2. Press and hold Program Button until the Program LED flashes ONCE and receiver will BEEP once.
3. Receiver LED will then give a long flash and beep.
4. This indicates receiver will be put into NORMAL-Power mode which consumes MORE power than LOW-Power mode.
START
A. Erase ALL Memory
1. Turn the Programming Selector to Position A.
2. Press and hold Program Button until the Program LED flashes ONCE and receiver will BEEP once. Press and hold button again, LED will flash
and receiver will beep again. Press and hold button a third time, LED will flash and receiver will beep a third time.
3. The receiver will then emit a long flash and long beep indicating ALL memory, including master transmitters have been erased from memory.
Press and
2 Sec.
Hold Program
Button
START
Press and
2 Sec.
Hold Program
Button
Quick Flash
and Beep
1 Sec.
Release
Button
Beep
Less than 10 Seconds Idle Time
1 Sec.
1 Sec.
Beep
Transmitter Programming Mode
Press and
2 Sec.
Hold Program
Button
Quick Flash
and Beep
Press and
2 Sec.
Hold Program
Button
Quick Flash
and Beep
Press and
Release
Hold Program
Button
Button
Beep
Release
Button
Long Flash
and Beep
Less than 10 Seconds Idle Time
1 Sec.
1 Sec.
Beep
Beep
Beep
Transmitter Programming Mode
Activate another
master Transmitter
Beep
Release
Button
Long Flash
and Beep
Release
Button
Long Flash
and Beep
2 Sec.
Release
Hold Program
Button
Beep
Indicates receiver will ignore facility code
FINISH
F
1 Sec.
Activate ONE MicroPLUS
or MicroCLIK™ master
Transmitter
1 Sec.
1 Sec.
After 10 Seconds
Timer Times-Out
Beep
Beep
Indicates receiver is in LOW-Power mode
FINISH
F
Indicates receiver is in NORMAL-Power mode
FINISH
F
Press and
2 Sec.
Release
Button
Button
Beep
®
Timer is Reset
to 10 Sec.
FINISH
ALL Memory has
been ERASED
Long
Beep
FINISH