Cutler-Hammer 8282A Kullanım Kılavuzu - Sayfa 2
Endüstriyel Elektrik Cutler-Hammer 8282A için çevrimiçi göz atın veya pdf Kullanım Kılavuzu indirin. Cutler-Hammer 8282A 2 sayfaları. 80 series photoelectric retriggerable one-shot logic card
Page 2
CONTROLS AND ADJUSTMENTS
The timing range and triggering mode are switch selected
according to the chart printed on the label. Paste the label on
the inside of the control module's side cover for future
reference. The length of the one-shot pulse may be varied,
within the range selected, by adjusting the pulse width
potentiometer (clockwise = increase). The 8282A is equipped
with a second potentiometer for adjusting the start up delay
period.
8282A
RETRIGGERABLE
ONE SHOT
TRANSITION
LT - DRK
DRK - LT
RANGE (SEC)
.01 - .20
.10 - 2.50
Slide the numbered switch upward for the "ON" position. In the
example below, 1 and 2 are set to "ON," and 3 is "OFF."
The one-shot pulse produced by the 8282A is transition
triggered, that is, a light or dark change in the infrared light
beam is used to start the one-shot timer pulse. Either the LT to
DRK, or DRK to LT transition may be selected to trigger the
one-shot. Note, however, that with the installation of a one-
shot logic card, the control module's output is governed by
the settings of the logic card rather than the status of the
infrared light beam. For the following timing diagrams,
assume that the LT to DRK transition has been selected as the
trigger.
Still Need Help?
Contact the
Cutler-Hammer Sensor
Application Engineers
1-800-426-9184
Fax: 425-513-5356
.4
INCR
TO 27
SEC.
PULSE
START UP
WIDTH
DELAY
S1
S2
S3
ON
OFF
--
OFF
ON
--
S1
S2
S3
--
--
OFF
--
--
ON
Cutler-Hammer
720 80th Street SW
Everett, WA 98203-6299
425/513-5300 Fax: 425/513-5302
www.cutlerhammer.eaton.com
Effective 5/20/97
Printed in U.S.A.
TIMING DIAGRAM:
Condition 1 - The power up delay period for the 8282A is user
adjustable from 0.4 to 27 seconds. The adjustable power up
delay prevents the one-shot from initiating any control action
until the machine or process being monitored reaches normal
operating speed.
Condition 2 - In this example, the LT to DRK transition has
been selected as the trigger; operation with the DRK to LT
transition is similar. The one-shot pulse starts at the first
appropriate transition following the power up delay period.
Note that the one-shot pulse length, "T", is constant regardless
of how long the infrared light beam is blocked.
Condition 3 - A retriggerable one-shot pulse, once started by a
LT/DRK transition, can be extended indefinitely if a LT/DRK
transition always occurs before the end of the preset time
period, "T".
1
LT
Control Module
Output
Dark
Mode
Light
Mode
104419 Rev 02
2
3
T
T
T
T
T
T
T
T
T