Beginning of season:

> Make sure that the electrical breaker for the pool heat pump is in the OFF position.
> Ensure the water lines and the heat pump are reconnected and/or drain valves are closed.
> Clean the pool filter and make sure the water is flowing adequately through the pool return line (5.1 m
> Complete your normal preparation and/or cleaning of the pool for the start of the season.
> Switch ON the breaker for the electrical supply to the heat pump.
> Then you need only start the unit and adjust the temperature to the desired value.

End of season (Winterizing)

> Switch OFF the breaker for the electrical supply to the heat pump.
> You must empty the unit of all water. Simply disconnect the WATER INLET and WATER OUTLET lines by unscrewing the
two union fittings on the front of the unit. To completely remove the water from the heat exchanger, you must remove the
drain cap (WINTERIZING DRAIN) that is located on the side of the unit. You must then let the water flow out until the unit is
completely emptied. (See the illustration below.)
It is recommended to cover the heat pump with a protective cover that is available from your dealer.