Alvarado CFG Kurulum ve Bakım Talimatları Kılavuzu - Sayfa 4

Eskrim & Kapılar Alvarado CFG için çevrimiçi göz atın veya pdf Kurulum ve Bakım Talimatları Kılavuzu indirin. Alvarado CFG 10 sayfaları. Bi-directional waist high security gate

Site Preparation

Use only skilled technicians for site preparation and installation of the gate using Alvarado's instructions.

Slab Requirements

Install gate on a solid, level concrete slab with a minimum thickness of 4".
Do not install the gate on asphalt.

Space Requirements

The following must be taken into consideration when determining space requirements:
Refer to the Plan and Elevation drawings below for gate dimensions.
Provide a minimum of 2" of space between the gate arm and adjacent barrier to prevent pinch points.
Fig. 1A
Fig. 1A
SSG/CSG Elevation View
39.76[ 1009.9 ]
39.76[ 1009.9 ]
35.50[ 901.6 ]
35.50[ 901.6 ]
Fig. 1B
Fig. 1B
SSG/CSG Plan View
NOTE

Gate Swing Configuration

The gate can be configured for right-hand, left-hand, or bi-directional swing [Figure 3].
Ensure the gate swing path does not open into a pedestrian walkway.
Fig. 3
Fig. 3
Gate Swing Directions
Right-Hand
Page 4
PUD3570R2-0
16.75[ 425.5 ]
16.75[ 425.5 ]
36.85[ 935.9 ]
36.85[ 935.9 ]
All dimensions are approximate.
For Assistance: [email protected] (909) 591-8431
CSG/SSG/CFG Installation and Maintenance Instructions
Fig. 2A
Fig. 2A
CFG Elevation View
Fig. 2B
Fig. 2B
CFG Plan View
Left-Hand
Bi-Directional
Created on: 10/7/2013
©Alvarado Mfg. Co., Inc.