5 - TROUBLESHOOTING
1. Softener fails
to regenerate
2. Softener delivers
hard water
3. Unit uses too much salt
4. Loss of water pressure
5. Loss of resin through
drain line
7
PROBLEM
A. Electrical service to unit has been interrupted.
B. Timer is not operating properly
C. Meter cable disconnected.
D. Jammed meter.
E. Defective valve drive motor.
F. Improper programming.
A. By-pass is opened.
B. No salt in the brine tank.
C. Injector or screen is blocked
D. Insufficient water into the brine tank
E. Hardness from the hot water tank.
F. Leak at the distributor tube.
G. Internal valve leak.
H. Flow meter jammed.
I. Flow meter disconnected.
J. Improper programming.
A. Improper brine refill setting
B. Excessive water in the brine tank.
C. Improper programming.
A. Iron build up in line to softener.
B. Iron build up in the softener.
C. Inlet of the valve plugged due
to foreign material.
A. Top distributor missing or broken.
B. Air in water system.
C. Drain line flow control
is the wrong size.
CAUSE
A. Assure permanent electrical service
(check fuse, pull chain or switch).
B. Replace the timer.
C. Check the meter connection to the
timer and the meter cover.
D. Clean or replace the meter.
E. Replace the drive motor.
F. Check the programming
A. Close the by-pass valve.
B. Add salt to the brine tank and
maintain the salt level above
the water level.
C. Replace or clean the injector
and screen.
D. Check the brine tank fill time and clean
the brine flow control if it's blocked.
E. Repeated flushing of the hot water
tank is required.
F. Make sure the distributor tube is not cracked.
Check the O' ring and tube pilot.
G. Replace seals and spacers
and/or piston.
H. Remove the obstruction from meter.
I. Check the meter connection
to the timer and the meter cap.
J. Check the programming
and reset as needed.
A. Check salt usage and salt setting.
B. See problem n°7.
C. Check the programming
and reset as needed.
A. Clean the line to the softener.
B. Clean the valve and resin bed.
C. Remove the piston and clean
the valve.
A. Add or replace the top distributor.
B. Ensure the presence of air check
system in the brine tank.
C. Ensure the drain line flow control
is sized correctly.
CORRECTION
and reset as needed.
7700 VALVE