4. Use nylon cable ties to secure the unit.
5. The AT1000 has four cables in the pigtail
cable harness:
a) Power (Red Wire)
b) Ground (Black Wire)
c) Input #1 (Orange)
d) Input #2 (Brown)
NOTE: If input wires are not used, wrap or tape
the wires separately to avoid short circuiting and
battery drainage.
6. Connect the unit to the external power
source:
• Power (Red Wire)
• Ground (Black Wire)
NOTE: The unit is adapted for 9-32V power supply.
ACTIVATION
To activate the unit, perform the following steps:
1. While the unit is in cradle (the Tamper Switch is pressed) press the
Emergency Button for at least 3 seconds. The Power LED will glow for
3 seconds.
2. After the Power LED ceases glowing, and the Network/Cell LED blinks,
stop pressing the Emergency button.
3. Verify that the Power LED blinks twice. This indicates successful
Network/Cell communication with the control center.
DEACTIVATION
To deactivate the unit, perform the following steps:
1. Dismount the unit from the cradle. Make sure the tamper switch is not
pressed.
2. Press the Emergency Button for at least 3 seconds. While the Emergency
Button is pressed, the Power LED glows for 2 seconds.
3. After the Power LED ceases glowing, stop pressing the Emergency Button.
For technical support call 1 800 220 0779 |