ETA Systems PD11VBC Kullanıcı El Kitabı - Sayfa 6
AC Güç Dağıtımı ETA Systems PD11VBC için çevrimiçi göz atın veya pdf Kullanıcı El Kitabı indirin. ETA Systems PD11VBC 8 sayfaları. Power protection series
FEATURE OVERVIEW
Switched Outlets Pushbutton:
LED Indicators:
1 of 2 Triggers that can activate a
Status indicator lights
turn-on or shutdown sequence for
for Switched Outlets,
Outlet Bank 2 and High-Current outlets.
DC Voltage Trigger,
Ground OK,
Line Fault
and Unsafe Voltage
15A Circuit Breaker:
Filtered Outlet Bank 1:
Filtered Outlet Bank 2:
Opens in the event that
Four Always-On, Balanced
Four switched, Balanced
equipment plugged into
Double L filtered outlets for
Double L filtered outlets for
the PD11VBC draws too
audio/video components that
audio/video components that
much current. When the
require constant power to
do not require constant power.
white button of the breaker
maintain programmed settings.
is visible, the breaker has
opened. Reduce the load
and push to reset.
IEC Main
Ground Lug:
Voltage Sense
Power
Provides a
Trigger Input:
Receptacle:
common
1/8 inch Mini-Plug jack.
Power cord
grounding point
Connect to a remote trigger
connects to this
for equipment
device that provides 12VDC to
receptacle.
with separate
trigger a startup/shutdown
ground leads.
sequence. This is the second
trigger that will activate the
PD11VBC turn-on or shutdown
sequence. (See switched out-
lets pushbutton on front panel).
4
1532 Enterprise Pkwy, Twinsburg OH 44087 • (800) 321-6699 • (330) 425-3388 • www.etasys.com
Voltmeter:
Meter Light Dimmer:
Convenience Outlet:
Controls brightness
Backlit analog meter
Provides a quick convenient
of the Voltmeter
measures incoming
way to plug in components
backlighting.
voltage source from
such as camcorders and
0-150 VAC.
video game systems.
High-Current Outlet Bank:
Satellite Coax Jacks:
Two delayed outlets designed for
Two pairs of gold plated
high-current components such as
F-Connectors optimized
amplifiers and powered subwoofers.
for Satellite TV signal
The current available to connected
line protection.
equipment is not limited by the
noise filtration components.
Voltage Sense
High-Current
Outlet Bank 2 Turn-
Trigger Output:
Outlets Turn-On
Off Switch:
1/8 inch Mini-Plug jack.
Switch:
3-position slide switch.
Connecting a 12VDC trig-
3-position slide switch.
Allows adjustment of the
ger to the Voltage Sense
Allows adjustment of
Turn-Off delay for Outlet
Circuit will allow the same
the Turn-On delay for
Bank 2. Choose
signal to pass through the
the two High-Current
between Always-On,
Voltage Sense Output to
Outlets. Choose
10 and 30 seconds.
control the startup/shut-
between 0, 10 and 30
down of an additional
seconds.
device.
FEATURE DETAILS
Cable TV Coax Jacks:
Two pairs of gold plated
F-Connectors optimized for
Cable TV and non-ampli-
fied Rooftop Antenna signal
line protection.
Telephone Jacks:
In/Out connections
for telephone line or
pay-per-view line
protection.
1532 Enterprise Pkwy, Twinsburg OH 44087 • (800) 321-6699 • (330) 425-3388 • www.etasys.com
Coaxial Line Protection
All coaxial cable sheaths from outdoors must be grounded to the building grounding electrode system
where they enter the building (per applicable NEC/CEC code). A driven ground rod is not adequate.
The PD11VBC provides application-specific protection for your satellite and cable TV equipment. Two lines of protection are
provided for each type. The satellite connections are for coaxial cables connected to a DBS (single or dual LNB) satellite
dish. The antenna connection is for a non-amplified rooftop antenna or cable TV line. The Additional TV connection pro-
tects the equipment plugged into the PD11VBC from "backdoor" surges in situations where the video signal runs to anoth-
er room for a downline TV.
Cable TV (Including HDTV) – TV tuners operate at approximately 10 millivolts (0.01 V) and utilize the frequency spec-
trum of 50Mhz to 950Mhz. The clamping level of the PD11VBC's cable TV protection circuitry is 700 millivolts (0.7 volts).
That's less than 1 volt above normal operating levels. The circuitry is shielded to prevent interference and has been opti-
mized to have less than 1dB of signal loss throughout the entire 50Mhz to 950Mhz range.
Satellite - Satellite dish LNB's can require up to 24 volts to operate and utilize the frequency range of 950Mhz to 2.2Ghz.
The clamping level of the PD11VBC's satellite protection circuitry is 27 volts - just 3 volts above the maximum operating
voltage. The circuitry is shielded to prevent interference and has been optimized to have less than 1dB of signal loss
throughout the entire 950Mhz to 2.2Ghz range.
Telephone Line Protection
Satellite TV receivers require a telephone line connection for Pay-Per-View services. The PD11VBC also provides surge pro-
tection for this line. One pair of RJ-11/45 compatible telephone jacks is provided for this. The circuitry utilizes auto-reset-
ting PTCRs and solid-state SIDACtors™ for reliability and unsurpassed protection. The clamping level of the PD11VBC's
telephone protector is 260 volts. This will allow typical ring voltage (90-130VAC) and operating battery voltage (-48DC)
to pass through the circuit and still protect the modem in your satellite receiver from damage.
Please note: The protection circuitry will not work if the phone lines are reversed. The incoming phone cable must be
connected to the "LINE" jack and the cable to the audio/video equipment must be connected to the "EQUIP" jack.
Power Cord
The PD11VBC comes equipped with a UL recognized, 10 foot, IEC320 power cord rated for 120V, 15-Amps, minimum 14
gauge wire and the cord secured to the enclosure with a cord retention bracket. The cord is not intended to be removed.
9