Operation
1 Set the unit with correct address code. If only one unit is connected to the system,
.
the address code must be set to "1". If there are multiple units, the order must be set
to "1,2,3,4 ... 8 ", and can only connect up to 8 units.
2 Connect the network cable according to the correct connection method (please refer to
.
the network cable port wiring definition diagram).
3 Connect the corresponding amplifier and speaker group to the corresponding ports
.
according to the correct wiring method
≤
) .
250W
4 When plugging and unplugging the network cable, you must ensure that other devices
.
connected to this device are powered off.
5 When connecting DC24V power supply
.
,
terminal
pay attention that the positive and negative cannot be connected in reverse
Connection Schematic
Technical Specification
Model
Channels
All channels output
total power
Single channel output
power
Power consumption
Power Supply
Dimension
Weight
(
Note
(
the current must be
To speaker
To amplifier
-
8 core network cable
F
LP
- ZS 10 12
-
12 channels
≤3000W
≤
250W
≤13 W
DC
24V
/10
00mA
485*1 5 5* 5 00 mm
.
2 0Kg
:
The total power to the single channel
≥
-
)
1A to the DC input
.