SPECIFICATIONS
Volts
~115V
Running AMPS
7.0
Startup AMPS
14.6
Frequency
60 Hz
Standard Hose Length
7 ft. (2.13m)
Dimensions
29.25 in. (.74m) H x 10.00 in. (0.25m) W
x 16.00 in. (0.40m) D
Air Line Pressure
35 psi (2.4 Bar)
Weight – Empty
44 lb. (20 kg)
Weight – Full
60 lb. (27 kg)
Shipping Weight
48 lb. (22 kg)
Flow Rate
4.05 oz./min (120ml/min)
10 |
TROUBLESHOOTING
NOTE: Do NOT use a chemical in the unit that is not a Clorox-
approved product. If you encounter the issues listed below, use the
suggested troubleshooting methods. If you encounter an issue that is
not addressed in this manual, contact Clorox Total 360™ Electrostatic
Sprayer support center at 1-800-492-9729.
Excessive nozzle dripping
Potential Issue
Damage to nozzle assembly
Damage to peristaltic pump tubing
Dirty exterior sprayer surfaces
System will not turn on or has shut off suddenly
Potential Issue
No power
System is not switched on
Compressor shuts off suddenly or
won't run while depressing the
sprayer trigger
Compressor has overheated
Corrective Action
Inspect for damage and faulty
parts. If present, contact the
Clorox Total 360™ Electrostatic
Sprayer support center service
department.
Replace pump tubing.
Clean exterior surfaces with
solvent (70–90% alcohol).
Corrective Action
Verify the unit is plugged in and
on a known working power outlet.
Depress power switch
to illuminate.
This is a sign that the unit's
circuit breaker has tripped or that
the compressor has overheated.
The user should look to see if
the white button (within its clear
moisture cover) has popped
out. If it has, the user should
power off the machine, look for
any physical objects that could
be loose or stuck in any of the
ventilation openings and clear/
dislodge. Press the button in and
then attempt to power the unit
back on. If the problem persists,
the user should let the unit sit
for 30 minutes to see if it's an
overheating issue. If the unit still
refuses to restart after a cool
down then they should contact
technical service.
Allow the unit to sit for a
minimum of 30 minutes
with the power off.