Sensors
The sensors must be connected to the exact ports on the screw terminals as illustrated below. Max current per port is
Minimum cable size depends on the distance to the sensor, please refer to the table below:
2
Distance
mm
<50 m
Min. 0.5 mm
50-100 m
Min. 0.75 mm
100-150 m
Min. 1.0 mm
Front LED
On completion of mounting, installation and powering up, the tree LEDs on the front will indicate the status of the iDOL 63.
dol-sensors a/s
AWG
2
Min. 20 AWG
2
Min. 18 AWG
2
Min. 17 AWG
Power LED – Green, ON
Status LED – Green, ON
Status LED – Green, flashing
Status LED – Red, ON
Status LED – Red, flashing
Figure 4: Label with MAC address can be found on the circuit board
Agro Food Park 15 - 8200 Aarhus N - T: +45 7217 5888 - F: +45 7217 5959
iDOL 63 is powered
iDOL 63 is connected to the internet
No connection to the internet
Internal error
Inernal memory full