closomat Palma Vita Kurulum ve Kullanım Kılavuzu - Sayfa 4

Tuvaletler closomat Palma Vita için çevrimiçi göz atın veya pdf Kurulum ve Kullanım Kılavuzu indirin. closomat Palma Vita 12 sayfaları.

closomat Palma Vita Kurulum ve Kullanım Kılavuzu
Palma Vita planning data
and service requirements
Key / Installation guide:
1. Determine unit height as standard or with optional points (P)
2. Locate floor & wall template jig to plan positions (J)
3. Locate waste pipe / soil position (S)
4. Locate cold water supply (W)
5. Locate electrical supply (E)
6. Use floor template jig for fixing frame (J)
Safe working load: 190kg/30st
Overall dimensions: 869mm high x 451mm wide x 730mm deep
D
S
E
W
S
F
W
Water services
Supplied with 15mm
Stainless steel braided
outer, EDM inner WRAS
approved exible hose.
(Please refer to page 2,
water services prior to
installation)
E
Electrical services
Supplied with 1000mm long,
three core (live/neutral/earth)
insulated 3183Y-1-white
control ex-cable, rated to
220-240V, 4.5A-4.9A.
(Please refer to page 2,
electrical services prior
to installation)
S
Waste details
Pan has a horizontal
spigot standard 100mm
diameter outlet, suitable
for standard pan
connection ttings.
4
J
Floor & Wall
Templates
Located in
Document Box
R
J
D
Rear wall fixing
Position 25mm to RH of
the centreline. 810mm
from the oor.
R
Rear oor xing (2No)
(Standards Installations)
Position on the oor
102mm from the rear wall.
119.5mm to each side of
the centreline.
F
Front oor xing (2No)
(When using Support Arms)
Position on the oor 327mm
from the rear wall. 119.5mm
to each side of the
centreline.
PALMA VITA
220-240V, 50Hz
4.5A-49A IPX4
10A
190kg
30st
Tel: +44 0800 374 076
www.closomat.co.uk