Cypress Suprex SPX-5600 Series Kullanım Kılavuzu - Sayfa 3
Genişletici Cypress Suprex SPX-5600 Series için çevrimiçi göz atın veya pdf Kullanım Kılavuzu indirin. Cypress Suprex SPX-5600 Series 20 sayfaları. Reader extender - rf wireless interface
1 - 8 to 16 VDC In
2 - Ground
Status LED
1 - exp (+)
2 - exp (-)
3 - +5 VDC out
4 - Prog Res 2
5 - Prog Res 1
6 - LED In
7 - D1/Data out
8 - D0/Clk out
1 - 8 to 16 VDC In
2 - Ground
Status LED
1 - exp (+)
2 - exp (-)
3 - +5 VDC out
4 - R4
5 - R3
6 - LED out
7 - D1/Data In
8 - D0/Clk In
Central Unit Settings
DIP Switch #1 ON
-Service Mode
DIP Switch #1 OFF
-Run Mode
1 2 3 4 5 6 7 8
Dip switch #4 is ON
-Disable Pullup resistors
Dip switch #4 is OFF
-Enable Pullup resistors
Wiegand
Wiegand / No Filter
Strobed Rising Edge (MR-5)
Strobed Rising Edge (Dorad0 644)
Strobed Rising (Mag-Tek)
Strobed Falling Edge
Reserved
Page 3 of 20
External connections and DIP Switch Settings
Switch
6 7 8
0
1
x
x = ON
2
x
3
x x
4 x
5 x
x
6 x x
7 x x x
F2F
SPX-5600
Central
SPX-5600
Remote
Remote Unit Settings
Dip switch #4 is ON
-Enable Pullup resistors
Dip switch #4 is OFF
-Disable Pullup resistors
Wiegand / No Filter
Strobed Rising Edge (MR-5)
Strobed Rising Edge (Dorad0 644)
Strobed Rising (Mag-Tek)
Strobed Falling Edge
1- Relay 4 N.O.
2- Relay 4 Com
3 - Relay 4 N.C.
4 - Relay 3 N.O.
5 - Relay 3 Com
6 - Relay 3 N.C.
7 - Ground
8 - Aux out
9 - R2 in
10 - R1 in
1- Relay 2 N.O.
2- Relay 2 Com
3 - Relay 2 N.C.
4 - Relay 1 N.O.
5 - Relay 1 Com
6 - Relay 1 N.C.
7 - Ground
8 - Aux in
9 - Not used
10 - Not used
DIP Switch #1 ON
-Service Mode
DIP Switch #1 OFF
-Run Mode
1 2 3 4 5 6 7 8
Switch
6 7 8
Wiegand
0
1
x
2
x
3
x x
4 x
5 x
x
6 x x
Reserved
7 x x x
F2F
x = ON