ASI 2045 Kullanım ve Servis Kılavuzu - Sayfa 6
Dişçilik ekipmanları ASI 2045 için çevrimiçi göz atın veya pdf Kullanım ve Servis Kılavuzu indirin. ASI 2045 20 sayfaları. Dental operative unit classic assistant’s cart
c
laSSic
Quick Start Up List
The operator is expected to fully read and understand all aspects of the operation manual for operation of this dental system.
The following is a brief condensed highlight of steps to use the system.
Verify Mechanical Integrity and Safe Use
proper operation. Ensure there are no missing parts or accessories. Carefully inspect components for tightness and the
absence of cracks, excessive wear or frayed electrical cords. If there is any adverse damage or the lack of mechanical integrity
that would prevent the safe use or operation of the system, it should not be used until repair or replacements correcting the
defects are made.
Verify Handpiece Placements
tubing is correctly situated. This system uses auto holders that activate the instrument once it is removed. If any instruments
are incorrectly placed into holders, the selected instrument by the operator will fail to work. Quick Check – Verify all tubings hanging straight
down are not crossed and are placed in sequential order from left to right on the holder bar. This will ensure they are placed correctly.
Verify Holder Switches are Active
disable function of that instrument if desired by the operator. Ensure all these levers are pointing straight down towards the
floor to ensure all holders are set to active. Otherwise an instrument may fail to operate when removed from the holder.
– Check and or fill water bottles appropriately and ensure the air pressure switch is turned on and that
Verify Water System
air pressure in the gauge reads approximately 30-35 psi.
Verify Handpiece Operation
Verify fiber optic illumination systems light and operation of other instruments. Water can also be sprayed from instruments to
ensure it is working correctly.
1.3 Dimensional Specifications, Capacities and Technical Data
Technical Specifications
Construction:
Finish:
Dimensions:
Water System
Reservoir Capacity:
Operating Pressure:
Aseptic, non-retracting water system.
Electrical System
Mains Power
115 Volts / 60 Hz or 220 Volts / 50 Hz
6
a
dvanced
– After unpacking the unit, look for any damage that could affect safe and
– Ensure all handpieces are placed into their correct holders and that the corresponding
– The auto handpiece holders feature a lock out switch levers which can be used to
– Handpiece instruments can be picked up and operated briefly by pressing the foot control.
High grade aluminum sheet metal
Baked-on powder coat
36" (91.44 cm) W
22.5" (57.15 cm) D
33.75" (85.725 cm) H
1.0 liter bottle
35 psi (2.5 bar)
ASI - The leader in Advanced Systems Integration www.asimedical.net
1044/1045/2044/2045
m
anual
Rev.A