When you reassemble PowerPal make sure that all parts are correctly in place and that
all bolts are tightened.
TROUBLESHOOTING
If any problems are encountered, check this section before contacting your Service
Center.
1. Head and flow conditions appear to be OK, but PowerPal will not work.
It is likely that the system has been installed incorrectly. Check this. If still not
working, remove the cap from the generator and use your fingers to quickly turn the
nut on top of the rotor. If the rotor begins to spin freely then PowerPal is working.
2. PowerPal has provided electricity for a while and suddenly the electricity stops.
If this instruction manual is not followed and power consumption is too high, or if
there is a short circuit in an appliance the fuse in the electronic load controller will
break. This will stop the electric current. It is important to replace this fuse with
another of the same size (see Technical Specifications below). If the fuse breaks and
an oversize fuse is inserted then the copper wiring in the stator may be damaged in the
future. If that happens the stator will need rewiring by an experienced motor rewirer.
3. Testing in the stream showed that PowerPal was capable of producing the rated
output power (200W, 500W or 1000W, depending on model). However, after
running the electrical cable to the house this output power was found to be less.
Due to resistance from the cable, long cable runs will result in a small loss of output
power. Power loss over a 100m cable run is approximately 10W. If the loss is greater
than this it means that the wrong diameter cable was used.
4. Power output has been falling recently.
Falling output suggests that the turbine is rotating more slowly than usual. Check that
the canal and propeller are free of leaves and other debris.
5. Frequency varies too much to safely use an appliance that is rated for use at a
specific frequency.
If an exact frequency is required for frequency-sensitive appliances it will be
necessary to attach a battery system.
6. An appliance is supposed to be grounded (earthed).
PowerPal is not grounded by its position in the stream. If grounding is required for
certain appliances it will be necessary to ground them separately. The usual method is
to run a wire from the earth pin to a metal stake in the ground outside.
PowerPal™ Low Head 11