Configuration
The EZ-3u is ready-to-run; simply connect a suitable trigger and desired outputs, then set the PRE, RUN, and
OFF stage potentiometers as required for the prop or display. Another feature of the EZ-3u that sets it apart
from similar controllers is the ability to configure the timing span for each potentiometer, as well as the pulse
output timing.
IMPORTANT: Disconnect any devices controlled by the Pulse or Audio outputs before entering the
configuration mode.
Power up (position 1) with configuration jumper installed; wait for flashing PRE LED.
While PRE LED is flashing, set PRE pot to desired zone. Press START to set
While RUN LED is flashing, set RUN pot to desired zone. Press START to set.
While OFF LED is flashing, set OFF pot to desired zone. Press START to set.
While PULSE LED is flashing, set RUN* pot to desired zone. Press START to set.
When all LEDs flash, your settings are saved. Power down and remove configuration jumper.
* Note: Setting the Pulse timing uses the RUN pot.
PRE Delay
RUN Time
OFF Time
PULSE / Audio
Values in parenthesis ( ) denote factory settings for PRE, RUN, OFF, and PULSE timing
4
Zone A
Zone B
( 0-10s )
0-20s
10-30s
( 10s-1m )
10-30s
( 10s-1m )
( 0.25s )
0.50s
Zone C
Zone D
0-30s
5-15s Random
10s-2m
10s-3m
10s-2m
10s-3m
1.00s
2.50s
EFX-TEK ● www.efx-tek.com ● [email protected]
Zone E
10-30s Random
10s-5m
10s-5m
5.00s