BLUEPOINT POWER LOADS
.27 Caliber - Power Load Strip
ITEM No.
COLOR
27LS11L3
Green
27LS11L4
Yellow
27LS11L5
Red
BLUEPOINT INSULATION WASHERS
.300" Dia. head, .145"-.157" step shank pin with 60mm dia. insulation
ITEM No.
INSULATION
THICKNESS
IF60-125-158S
1"- 1 1/4"
IF60-200-200S
2"
IF60-300-200S
3"
IF60-400-200S
4"
IF60-500-200S
5"
IF60-600-200S
6"
POWER LEVEL
Low
Medium
Strong
PENETRATION
1"
1"
1"
1"
1"
1"
26
MAINTENANCE
TOOLS NOT MAINTAINED PROPERLY CAN CAUSE SERIOUS INJURIES TO
TOOL OPERATORS AND BYSTANDERS. CLEAN TOOLS AT LEAST ONCE A
WEEK OR AFTER 1000 SHOTS.
Always ensure that the tool is unloaded and use safety goggles before
performing any service or repair.
COMPLETE CLEANING / GENERAL MAINTENANCE
Heavy or constant exposure to dirt and debris may require that the tool be
cleaned more extensively. Complete disassembly and cleaning of all parts
may be necessary to restore the tool to normal operation. General
maintenance should be performed every week or more often if the tool is
subjected to heavy use.
ALWAYS FUNCTION TEST THE TOOL AFTER PERFORMING ANY SERVICE.
CARE AND MAINTENANCE
Care of the tool
The outer casing of the tool is manufactured from impact resistant
plastic. The grip comprises a synthetic rubber section. The ventilation slots
must be unobstructed and kept clean at all times. Do not permit foreign
objects to enter the interior of the tool. Use a slightly damp cloth to clean
the outside of the tool at regular intervals. Do not use a spray or steam-
cleaning system for cleaning.
Maintenance
Check all external parts of the tool for damage at regular intervals and check
that all controls operate properly. Do not operate the tool when parts are
damaged or when the controls do not operate properly. When necessary,
have the tool repaired by an authorized repair center.
Servicing the tool
The tool should be serviced when
any of the following occur:
1. Cartridges misfire.
2. Fastener driving power is
inconsistent.
3. You notice that:
contact pressure increases, trigger
force increases, power regulation is
difficult to adjust (stiff), the
cartridge strip is difficult to remove.
WARNING!
•
The tool gets hot when
in use.
•
DO NOT disassemble
the tool when it is hot.
27