INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS
FOR COOKER HOODS FOR WALL FITTING 230 Vac - 50 Hz
The equipment is constructed in accordance with European Standards and the requirements
included in the following Directives: 72/23 EEC (electric-low tension safety), 89/336 EEC
(electromagnetic compatibility), 93/68 EEC ( EC marking regulations).
Before installing and/or using the hood:
• read all the instructions thoroughly;
• make sure that the voltage (V) and frequency (Hz) rating indicated on the plate inside the
hood unit correspond to the mains supply available;
We recommend that the equipment be installed by expert personnel.
Installation
This hood can be used as an extractor or a
filtering unit. The unit must be fitted at a distance
of at least 65cm (75cm upon gas hobs) for the
cooking hob. It must not be mounted above
cookers fitted with top radiant plate. The
contaminated air mist be discharged in a manner
complying with current regulations.
Two different wall-mounting systems are used,
depending on the model (Fig. 1-2).
) Handling and leveling brackets
) Retaining screws
C) Hood/flue securing screws (just where it's
provided)
D) Flue/wall bracket and securing screws.
Fig. 2
Extractor (fume exhausted externally). Cooking fumes are
conveyed away from the kitchen to the outdoor environment
by way of ducting. Connect said tube with suitable diameter
to the junction supplied (Fig. 3) The tube should have its
outlet outside the house.
This pipe must not under any circumstances be connected to
cooker, boiler or burner exhaust pipes, etc.
If the hood is operated in suction whilst stove, gas cooker,
fuel-fed boilers, etc are being used, ventilation from outdoors
must be provided.
The suction model is not fitted with a carbon filter.