ACR Electronics RCL-50B Ürün Destek Kılavuzu - Sayfa 13

Taşkın Işık ACR Electronics RCL-50B için çevrimiçi göz atın veya pdf Ürün Destek Kılavuzu indirin. ACR Electronics RCL-50B 19 sayfaları. Remote control searchlight master controller point pad

NOTE: The Searchlight should not be covered while the XRCiZ feature is enabled.
The URC-102 Master Controller provides optimum voltage to ensure the brightest Searchlight
performance and long bulb life. Also to extend lamp life, the Master Controller has a timed
lamp power up feature. The Searchlight lamp reaches full intensity within 2 seconds.
The URC-102 Master Controller has a Searchlight motor timeout feature. If a Point Pad™
rotation switch (right or left) is continuously engaged for more than 50 seconds, the Master
Controller will interrupt the operation until the Point Pad™ switch is disengaged. This feature
will save the Searchlight motor from burnout due to accidental activation. The elevation motor
has similar features which will timeout in approximately 20 seconds.
FIGURE 7: URC-102 MASTER CONTROLLER WIRING DIAGRAM
11
Y1-03-0141 Rev. B