Troubleshooting
Pilot sparks but does not light –
No gas to fire, check isolators are open.
Pipework blockage, clean out.
Air not fully purged, repurge supply or wait longer.
Spark earthing to metal work, reset gap correctly.
Check for spilled ceramics in pilot area.
Blocked pilot, clean out internally.
Pilot lights but then goes out –
Severe restriction in gas supply, clear obstruction.
Faulty thermocouple, replace pilot unit.
Hold control knob in for longer.
Check control knob does not foul control plate.
Fire does not spark at pilot –
HT lead detached, refit.
Spark gap too large or small, reset correctly.
Faulty piezo unit, replace.
Debris shorting out electrode, clean.
Fire runs for a time and then cuts off –
Excessive room draught or flue pull, rectify.
Loose or faulty thermocouple, rectify.
TTB system in operation.
Lint in pilot aeration hole, clean thoroughly internally
Pilot flame shrinks when fire is on high –
Poor gas flow to fire, check pressure with fire on high.
If pressure is low, remove any restriction in pipework or valve.
Check all isolators are adequately sized and fully open.
Check meter pressure is adequate.
Lint in pilot aeration hole, clean thoroughly internally.
Fire smells when first lit or in use –
Newness smell from brand new appliance.
Spillage occurring. Carry out spillage test and rectify any
problems.
Low temperature sealants or combustible materials used in
incorrect positions
Failure of the fire not lighting remotely, may require new batteries been fitted to the hand set and receiver.
It is recommended to replace the batteries when the fire is been serviced on a yearly basis.
Guarantee
The guarantee is valid for a period of 2 years from the purchase date. This guarantee does not
cover parts normally subject to wear or which last less than the aforementioned Guarantee period, as
thermocouples, batteries, gaskets, painted parts, logs or stones. The ceramic glass is not included in the
guarantee.
The guarantee will be invalided by incorrect installation or misuse of the appliance.
During this period the Dealer undertakes to repair or replace the faulty parts. Such repairs shall not alter