e)
Five Piece Log Set.
A
PPLIANCE DATA
GAS TYPE
SUPPLY PRESSURE
HEAT INPUT
GAS RATE
INJECTOR SIZE
GAS CONNECTION
ELECTRICAL
Burner Pressure
NO
Concentration
X
G
I
ENERAL
NSTALLATION

Fitting the Appliance

1
This installation must be carried out in accordance with all local laws and regulations.
2
The 526 Convector can be fitted into fireplace openings which are large enough or can
be altered to accept this appliance. The dimensions are shown in Figure 1. If the
fireplace has to be altered a lintel may be required to
support the masonry over the opening.
The fireplace opening should be formed
from or lined with non-combustible
material.
3
The installation must meet the requirements of the
current CE regulations.
4

The Hearth

The hearth supporting the appliance within the fireplace
must be made of a non combustible material at least
12mm in thickness.
Because of the heat radiated from this appliance the hearth should extend 250mm in
front of the appliance. Alternatively the appliance may be installed 250mm above finished
floor level without requiring the extended hearth.
5

The Chimney Flue

The following types of chimney or flues are acceptable:
a)
A conventional open flue connected with a short length of 100mm diameter flue
pipe and a register plate or lined with a flexible flue liner of at least 100mm
diameter T250 rating.
b)
A 100mm diameter (or larger) gas flue
The flue must have a minimum effective height of 3 metres. 90º bends are not allowed.
ACF526NG
NATURAL GAS
20mb
6.8kW Net
0.72m/h
Ø
2.1 mm
17,5mbr
R
EQUIREMENTS
8mm COMPRESSION
230V / 50Hz / 3A
Class 5
FIGURE 1
4
ACF7526P
PROPANE
37mb
6.6kW Net
0.2m/h
512g/hr
Ø
1.35mm
27mbr