Ambionair TDG8000-3 Kullanıcı El Kitabı - Sayfa 15

Taşınabilir Jeneratör Ambionair TDG8000-3 için çevrimiçi göz atın veya pdf Kullanıcı El Kitabı indirin. Ambionair TDG8000-3 17 sayfaları. Air-cooled diesel generator

Replace engine oil
Remove the oil filler cap. Remove the drain plug and drain the old oil while the engine is
still warm. The plug is located on the bottom of the cylinder block. Tighten the drain plug
and refill with the recommended oil.

Air filter maintenance

Clean the air filter every 6 months or 500 hours of operation, whichever comes first. If
necessary, exchange it. Do not use detergent to clean the air filter element.
Note: Never start the engine without the air filter. This can cause serious
damage to the engine if foreign objects enter the intake system. Always

Fuel filter maintenance

change the air filter on time.
The fuel filter should be cleaned often to keep the engine running at maximum
performance. The recommended time period for cleaning the fuel filter is 6 months or
500 hours of operation whichever comes first.
To clean the fuel filter, first drain the fuel from the fuel tank. Loosen the small screws on
the fuel switch and remove the fuel filter from the port. Use diesel fuel to clean the fuel
filter. Also, remove the fuel injector and clean the carbon deposit around it. The
recommended time period for this is 3 months or 100 hour
oil filter
drain plug
oil filler cap/dipstick
s, whichever comes first.
15