Ambirad Apollo QHL 90-3 Kullanım Kılavuzu - Sayfa 5

Isıtıcı Ambirad Apollo QHL 90-3 için çevrimiçi göz atın veya pdf Kullanım Kılavuzu indirin. Ambirad Apollo QHL 90-3 20 sayfaları. Quartz glow instant infra-red heaters

Ambirad Apollo QHL 90-3 Kullanım Kılavuzu

1.3.1 Apollo range:

The heater must be mounted in such a way
that the halogen lamp does not slant more
than 4° from the horizontal, when viewed
from the front.
The heater is suitable for installation only on
a normally non-flammable surface. Observe
the minimum safe distance between the
heater body and inflammable surfaces
when mounting.
Do not position the heater near to furniture
or curtains as this could present a fire
hazard.
Refer to Table 1 for the recommended
mounting height for the heater.
Keep out of the reach of children.
1. Separate the heater from the mounting
bracket by loosening the two nuts at the
rear of the heater.
2. Securely fasten the bracket to the mounting
surface using the fixing holes in the bracket.
3. Replace the heater on the bracket using the
nut and bolt supplied and fix in the required
angular position by tightening the fixing bolt
on the bracket. See diagram below.
Always isolate the heater from the mains supply
when adjusting the angular position
1.3.2 Sorrento range:
1.3.2.1 General
• Always allow the heater to cool before
attempting
to
attempt to move the heater while it is
switched on!
• Observe
the
minimum
between the heater body and inflammable
surfaces and objects when mounting.
• When ceiling hanging any Sorrento heater,
ensure the minimum distance from the
ceiling is adhered to.
• Please
refer
to
recommended positioning of the heater with
regards to minimum distances.
• When wall mounting any Sorrento heater,
secure the supply cable ensuring it is not
resting on the body or obstructing any air
vents.
• When wall mounting any Sorrento heater,
the heater should be mounted with the
terminal box at the bottom of the unit.
• Do not install the heater in a corner!
• Keep out of the reach of children.
Always isolate the heater from the mains
supply when adjusting the angular position.
1.3.2.2 Single units SOR 15/DL30/TW45
• The Sorrento heater in singular format can
be either hung from a ceiling from chains
(not supplied) or wall mounted horizontally.
In addition, the SOR15 can be wall mounted
vertically.
• When wall mounting the Sorrento heater
horizontally, do not position the heater at an
angle more than 90° and less than 30° as
shown below.
reposition/move.
Never
safe
distance
Table
1
for
the