ACR STOVES MAL2CL Посібник - Сторінка 6
Переглянути онлайн або завантажити pdf Посібник для Дров'яна піч ACR STOVES MAL2CL. ACR STOVES MAL2CL 17 сторінок.
Malvern manual MAL2CLASSIC 0916-1 28/10/2016 11:45 Page 6
This appliance is equipped with a pre-fitted manufacturers smoke exempt stop. Under
no circumstances should it be tampered with or removed unless expressly authorised
by a competent person and the appliance is not installed in a smoke exempt area.
If the appliance is to be installed in a non smoke exempt area you can remove the
restricting screw on the secondary air control (on right hand side under the ash lip)
to allow full movement of the secondary air slider.
The appliance is supplied pre-assembled with the flue spigot in the top exit position.
If you intend to install the appliance using a rear flue connection, the blanking plate should be
swapped over as follows:
• Remove the internal vermiculite baffle
(for further instruction please see
under maintenance heading).
Assembly of the unit
• Remove the rear metal cut out plate
from the back of the stove
• Remove the rear blanking plate
• Remove the flue spigot from the top
exit by removing the securing bolts
and rope seal
• Refit the rope seal and flue spigot to
the rear exit and secure with the bolts
• Refit the blanking plate to the top exit
using the rope seal and retaining bolts