INTRODUCTION 
Thank you for purchasing this desktop CO2 
monitor. It measures carbon dioxide levels, air 
temperature and humidity. This makes it ideal for 
indoor air quality (IAQ) diagnosis and HVAC system 
performance verification. 
 
Poor indoor air quality is considered unhealthy. It 
can lead to drowsiness, inability to concentrate, 
and even illness (for example, Sick Building 
Syndrome). 
 
IAQ monitoring of CO2 levels is widely used in 
public areas such as offices, classrooms, factories, 
hospitals and hotels. It is also recommended for 
industrial hygiene in some countries. (See 
appendix). 
 
Product Features: 
● Large display shows CO2 level, temperature, 
    humidity, date and time 
● 15 degree tilt angle makes the display easy 
    to see and read 
● Indoor air quality level indication: 
    Good, Normal, and Poor 
● Stable NDIR sensor for CO2 detection 
● Visible and audible CO2 warning alarm 
● ABC (Automatic Baseline Calibration) 
    or manual CO2 calibration 
● Maximum or minimum CO2 level recall 
    function 
 
 
MATERIALS SUPPLIED 
This package contains: 
● Meter 
● Power Supply (5V +/‐ 10%, >= 0.5A) 
● Manual 
 
POWER SUPPLY 
The meter is powered by an AC adaptor 
(5V/0.5A output). 
LCD DISPLAY 
Symbols 
ppm                  CO2 level in parts‐per‐million 
GOOD                CO2 is in good level 
 
NORMAL            CO2 is in normal level 
POOR                CO2 is in poor level 
 
Air Temp.          Air temperature 
Humidity %        Unit of air relative humidity 
o
E (C/F)              Celsius/Fahrenheit of temp. 
MAX/MIN          Maximum/Minimum readings 
                          CO2 alarm icon 
 
NOTE:   
TWA / STEL / VENT.R / cfm/p / lps% icons 
are not used for this model. 
 
 
KEYPAD 
SET ‐Enter setup mode 
‐Save and finish settings 
ESC‐Exit setup page / mode 
      ‐Terminate CO2 calibration 
Reset ‐ Clear MAX/MIN values 
▲‐Select mode or increase value in setup 
MIN/MAX▼ ‐Activate MAX, MIN function 
‐Select mode or decrease value 
during setup 
SET+▲+MIN/MAX▼ ‐ CO2 calibration mode 
 
OPERATION 
POWER ON/OFF 
Plug the wall adaptor into an appropriate 
receptacle. The meter will turn on automatically 
after a short beep. The lit LED indicates full power. 
If the voltage is too high or low, "bAt" will display 
on the LCD and the LED will flash. Please see page 
14 for trouble shooting. 
 
During normal operation, the LCD will display the 
current CO2 level in ppm, air quality level, air 
temperature, humidity, and the current date and 
time (Fig.1). 
 
 
 
 
 
 
 
 
TAKING MEASUREMENTS 
The meter starts taking measurements 
immediately after it is turned on and updates the 
readings every second. In the event the operating 
 
environment is quickly changed (for example, from 
 
high to low temperature), it will take 
 
approximately 2 minutes for the CO2 and 
 
temperature to adjust and 10 minutes for humidity 
 
to stabilize. 
 
NOTE: Do not hold the meter close to your face as 
 
your breath will affect the CO2 level. 
 
MIN/MAX 
While the meter is powered on, press the 
"MIN/MAX▼" button to see the minimum and 
maximum CO2 level, temperature, and humidity in 
turn. Each press of "MIN/MAX▼" will display the 
MIN and MAX values in order, then return the 
meter to normal mode (Fig.2). 
 
During normal operation or while viewing 
MIN/MAX levels, press and hold the "RESET" key 
for more than 1 second to clear the stored 
minimum and maximum values. 
 
 
 
 
 
 
 
 
ALARM 
The meter features an audible alarm that warns 
the user when the CO2 concentration exceeds the 
programmed limit. Users can set 2 limits: a CO2 
level that requires ventilation (See P1.
setting alarm limits) and a lower CO2 level when 
ventilation is no longer required (See P1.
CO2 normal limit). 
 
During high alarm, the meter emits an 80dB beep 
and displays the fan icon on the LCD. The alarm 
can be temporarily stopped by pressing any button, 
or it will automatically stop when the CO2 level 
falls below the lower limit.   
 
If the alarm is temporarily silenced, it will resume 
if the CO2 level fall below the lower limit then rises 
above the upper limit again, or if the 
"RESET" button is pressed to re‐activate the alarm. 
 
HIGH CO2 ALARM 
 in setup for 
3
 in setup 
2