Coachmen RV Cross Trail Посібник користувача - Сторінка 6
Переглянути онлайн або завантажити pdf Посібник користувача для Будинки на колесах Coachmen RV Cross Trail. Coachmen RV Cross Trail 10 сторінок. For renogy rego
Electrical Connections
The unit is equipped with a 30A 120VAC "shore power" connection. The 30A connection is always best,
however, if a connection of less than 120VAC 30A is going to be used, the inverter/charger charge rate may
need to be reduced, refer to "Shore Settings" below.
Shore Settings
The only adjustment needed to the inverter is to change the AC Charging Current. See below on how to
change the utility charging current.
How to change to Lithium Battery type and settings for RBT12400LFPL-SHBT battery
1. Hold down right button until it shows 00
2. Press up/down arrows and go to 05
3. Hold right arrow
4. Press up/down arrow and change to b-0
5. Hold right arrow to make change
6. Set 94 to ALb, set 26 to 14.4V, Set 27 to 13.2V, right arrow to save
7. Press left button to return to main screen
8. To save, turn off inverter and then back on
How to Change Inverter Charge Current Parameter
1. Hold right back arrow button on Inverter to enter parameter settings
2. Press UP or DOWN and go to Parameter 11 and then press right button
3. Parameter setting will begin to flash, then change the AC Charging
Current from 0-75A by intervals of 5A to desired charging current
4. Press Right button to accept change
5. Press Left button to exit setting menu
6. Turn inverter off and then back on with the remote button to save setting