Accuracy is given at 18 o C to 28 o C (65 o F to 83 o F),
less than 70 % RH
DC Voltage
Range
Resolution
600.0mV
0.1mV
6.000V
1mV
60.00V
10mV
600.0V
100mV
1000V
1V
Input Impedance: 7.8M.
Maximum Input: 1000V dc or 1000V ac rms.
AC Voltage
Range
Resolution
6.000V
1mV
60.00V
10mV
600.0V
100mV
1000V
1V
Input Impedance: 7.8M.
Frequency Range:50 to 60Hz
Maximum Input: 1000V dc or 1000V ac rms.
DC Current
Range
Resolution
6A
1mA
10A
10mA
Overload Protection: 10A / 250V Fuse.
Maximum Input: 10A dc or ac rms on 10A DC range.
AC Current
Range
Resolution
6A
1mA
10A
10mA
Overload Protection: 10A / 250V Fuse.
Frequency Range: 50 to 60 Hz
Maximum Input: 10A dc or ac rms on 10A AC range.
Resistance
Range
Resolution
600.0
0.1
6.000k
1
60.00k
10
600.0k
100
6.000M
1k
60.00M
10k
Maximum Input: 600V dc or 600V ac rms.
Accuracy
+0.5% of rdg + 2 dgts
+1.2% of rdg + 2 dgts
+1.5% of rdg + 2 dgts
Accuracy
+1.5% of rdg + 10 dgts
+1.5% of rdg + 10 dgts
+2.0% of rdg + 10 dgts
Accuracy
+2.5% of rdg + 5 dgts
Accuracy
+3.0% of rdg + 5 dgts
Accuracy
+1.2% of rdg + 4 dgts
+1.0% of rdg + 2 dgts
+1.2% of rdg + 2 dgts
+2.0% of rdg + 2 dgts
+5.0% of rdg + 10 dgts
Capacitance (Auto-ranging)
Range
Resolution
40.00nF
10pF
400.0nF
0.1nF
4.000uF
1nF
40.00uF
10nF
400.0uF
0.1uF
4000uF
1uF
6
Maximum Input:
00V dc or
Frequency (Auto-ranging)
Range
Resolution
9.999Hz
0.001Hz
99.99Hz
0.01Hz
999.9Hz
0.1Hz
9.999kHz
1Hz
99.99kHz
10Hz
999.9kHz
100Hz
10MHz
1kHz
Sensitivity: >0.5V RMS while ≤ 1MHz ;
Sensitivity: >3V RMS while >1MHz ;
Maximum Input: 600V dc or 600V ac rms.
Temperature
Range
Resolution
-20 o C~+760 o C
1 o C
-4 o F~+1400 o F
1 o F
Sensor: Type K Thermocouple
Overload protection: 600V dc or ac rms..
Diode Test
Test current
Resolution
0.3mA
1 mV
typical
Open circuit voltage: 1.5V dc typical
Overload protection: 600V dc or ac rms.
Audible continuity
Audible threshold: Less than 100 Test current:
<0.3mA
Overload protection: 600V dc or ac rms.
OPERATION
WARNING: Risk of electrocution. High-voltage
circuits, both AC and DC, are very dangerous and
should be measured with great care.
1.
ALWAYS turn the function switch to the OFF
position when the meter is not in use. This meter
Accuracy
+5.0% of rdg + 50 dgts
+3.0% of rdg + 5 dgts
+5.0% of rdg + 5 dgts
+5.0% of rdg + 5 dgts
6
00V ac rms.
Accuracy
+1.5% of rdg + 5 dgts
+1.2% of rdg + 3 dgts
+1.5% of rdg + 4 dgts
Accuracy
+3% of rdg
+5 o C/9 o F
Accuracy
+10% of rdg + 5 dgts