dealt with by advising the technical parameters or a stilling tube.
2.1.3 hints for solid surface conditions
 For fine-grained solids, the sensor must be aligned with the product
surface.
2.1.4 hints for in-tank effects
 Stirrers or agitators can cause a vortex. Mount the transmitter off-center
of any vortex to maximize the return echo.
 In non-linear tanks with rounded or conical bottoms, mount the
transmitter off-center. If needed, a perforated reflector plate can be
installed on the tank bottom directly under the transmitter center line
to ensure a satisfactory return echo.
 Avoid mounting the transmitter directly above pumps because the
transmitter will detect the pump casing as the liquid falls away.
 When install to the cold area, should choose the lengthen sensor of the
level meter ,make the sensor extend into the container, shun frost
and icing .

2.2 Mounting

2.2.1 dimensions
www..aktek.com.tr