Aero-ALERT™ Alarm Kit
P/N: 100343, 101893, 101894
Function:
The Aero-ALERT™ alarm kit is designed to produce a visual and
audible signal when the Aero-Stream® product has an air output
of less than 1 PSI or a high water event with the optional high
water float switch. The product has a "mute" function to turn off
the alarm. The alarm will not function in the "mute" mode. In the
event of an alarm signal see the troubleshooting section below.
Service and Maintenance
The alarm is designed to produce the audible signal for at least 60
days and visual signal for at least 30 continuous days on the self
contained batteries. The batteries should be replaced annually. It
is suggested that they be replaced at the same time as your fire
detection smoke alarm in your home.
Directions
1.
Install the air line/tee fitting in the output air line of the Aero-
Stream® unit. Clamp the air line with plastic clamp (figure 2).
2.
Connect the 1/8" air line from the tee to the black barbed
fitting on the bottom of the Aero-ALERT™ (figure 3).
3.
Push the Aero-ALERT™ post into the ground 3" - 5". If the
earth is hard use a ¾" diameter wood or metal stake and a
hammer to make a 3" - 5" deep holes. Push the Aero-ALERT™
post into the formed hole. DO NOT HAMMER ON THE Aero-
ALERT™.
Troubleshooting
The light illuminates for two conditions, either a signal from the air
switch or a signal from the float switch. Follow the steps below to
determine the cause of the alarm.
1. Unplug the float from the alarm box. If the light goes out go to
step 4. If the light does not go out go to step 2 (figure 4).
2. Make sure the large air line connections are not leaking. If not
leaking go to step 3 (figure 2).
.
3. Make sure the small air line is tightly connected to the black
"tee" and the fitting on the bottom of the alarm box. If the
PN 101953
Figure 1
To
Alarm
Figure 2
From
Tee
Figure 3
To Tank