AeroAudio MOS - UNO - IP Посібник - Сторінка 2
Переглянути онлайн або завантажити pdf Посібник для Стереосистема AeroAudio MOS - UNO - IP. AeroAudio MOS - UNO - IP 9 сторінок.
MOS - UNO - IP
MANUAL
GPI control:
Pin
Function
1
GPI voltage control
2
GPI close contact to GND
3
4
5
RESET settings
6
GND GPI voltage vontrol
7
GND switch contact
8
GND switch contact
9
GND switch contact
Settings: through internal webpage, default IP address 192.168.0.101
Reset settings to factory default:
- Power off the MOS-UNO-IP
- Connect Pin 5 to pin 7,8 or 9
- Power on the MOS-UNO-IP and wait for 5 seconds, during boot the status LED will blink
fast in red. After the reset boot the satus LED will turn white and facory default settings are
restored. The MOS-UNO-IP can be reached at 192.168.0.101 again.
GPI schematic:
STEENWEG 148C - 9810 NAZARETH - BELGIUM - T +32 (0)9 396 76 40 - [email protected]
Signal
+5 till +15 volt DC
Contact to pin 7,8 of 9
Contact to pin 7,8 of 9