Bobrick SureFlo 824 Інструкції з монтажу, експлуатації, обслуговування
Переглянути онлайн або завантажити pdf Інструкції з монтажу, експлуатації, обслуговування для Сантехніка для ванної кімнати Bobrick SureFlo 824. Bobrick SureFlo 824 4 сторінки. Automatic, counter-mounted soap dispenser
To Operate:
1. Prime Unit – After filling
dispenser, plug in power
to start prime. If unit is
plugged in prior to filling
dispenser, place hand
under spout within sensor
location to start prime.
2. Standard Dispense –
Place hand under spout
1-1/2"
within the sensor location
40mm
1/4"
6mm
for approximately 1/2
1-1/4"
32mm
second to dispense
Activation
Area
controlled amount of
liquid hand soap.
Routine Cleaning and Maintenance:
Using a damp cloth, wipe the chrome-plated exterior of the dispenser daily. Periodically (about 3 to 6 months), it is
recommended to flush the system with lukewarm water for cleaning and maintenance.
1. When minimal amount of soap is left in the bottle, fill dispenser with lukewarm water from top to dilute soap.
2. Press the Automatic System Flush Button to flush the system.
3. Once unit is flushed, press the Automatic System Flush Button again to stop dispensing.
4. Fill unit with fresh soap and dispense as usual.
Troubleshooting:
1. Soap dispenser does not dispense soap, but you can hear motor running. The green LED lights up when hands are
under spout.
a. Press the Automatic System Flush Button until soap comes out
b. Press the Automatic System Flush Button again to turn it off
2. Soap dispenser does not dispense soap and you cannot hear motor running. The green LED does not light up when hands
are under spout.
a. Be sure power is supplied to unit.
b. Make sure Fiber Optic Nut is tight on Fiber Optic Port.
Warranty:
SureFlo Automatic Liquid Soap Dispenser is warranted to be free from defects in workmanship and material under normal
usage from the date of purchase for a period of 3 years.
In the United States: BOBRICK WASHROOM EQUIPMENT, INC.
New York: 200 Commerce Drive, Clifton Park, NY 12065-1350 • Tel: (518) 877-7444 • Fax: (518)-877-5029
Los Angeles: 6901 Tujunga Ave, North Hollywood, CA 91605-6213 • Tel: (818) 982-9600 • Fax: (818)-503-9287
or email [email protected]
In Canada: BOBRICK WASHROOM EQUIPMENT COMPANY
45 Rolark Drive, Scarborough, Ontario M1R 3B1 • Eastern Canada: Tel: (877) 423-6555 • Fax: (877) 423-8555
© 2020 by Bobrick Washroom Equipment, Inc.
• Western Canada: Tel: (877) 423-6444 • Fax: (877) 423-8444 or email [email protected]
Form No. 824-391 r7/22/20
Printed in U.S.A.
3. Adjusting amount of soap
dispensed – Depending on
viscosity of liquid soap used,
unit may dispense between
0.4 ml to 3 ml of soap. To
reduce output of liquid soap,
rotate Portion Control Knob
counter-clockwise. To
increase the output of liquid
soap, turn the knob clockwise.
4. LED Light Indicators –
When activated, solid
green LED will light.
If green light is flashing,
remove hand to allow
unit to reset, then activate
again. Flashing red LED
light indicates time to
replace batteries.
4
SureFlo
Automatic, Counter-Mounted Soap Dispenser
®
INSTRUCTIONS FOR INSTALLATION, OPERATION & MAINTENANCE
BOBRICK MODEL B-824 LIQUID SOAP DISPENSER
Clearances and Mounting Requirements:
• 1-3/8" (35mm) diameter mounting hole required.
• Minimum 18" (457mm) vertical clearance needed below the counter.
• 5" (127mm) diameter clearance needed below the mounting hole to
accommodate bottle and bottom housing.
• Minimum 2-1/4" (57mm) diameter clearance needed for Mounting nut directly
below the counter to clear sink rim.
• Recommend drilling mounting hole 6" to 8" (152 to 203mm) from the wall,
and 2-1/2" to 3" (64 to 76mm) from sink rim.
For New Installation:
• Refer to mounting template for drilling locations (Form No. 824-307).
For Retrofit:
1.
Remove existing dispenser(s).
2.
Clean area.
3.
Ensure hole is 1-3/8" (35mm) diameter.
4.
If necessary, enlarge opening using appropriate hole saw. For granite/marble counters, recommend using a diamond
hole saw (consult with stone and granite specialist). If needed, mounting hole should be offset to clear the sink rim. The Mounting
Nut requires 2-1/4" (57mm) diameter clearance directly below the counter.
Unit Diagram:
Item
Description
1
Top Assembly with Spout, Door and Stem
2
LED Light Pipe
3
Liquid Nozzle Tip
4
Fiber Optic Insert with Sensor Lenses
5
Rubber Counter Gasket
6
Wave Washer
7
Mounting Nut
8
Stem Mounting Nut
9
Duckbill Housing
10
Bottom Housing Assembly (includes Soap Bottle)
11
Battery Pack (requires (4) "D" cell alkaline batteries
not included)
12
(3) Fiber Optic Cables for Sensor and LED Light Pipe
13
Fiber Optic Connector Tip Assembly
14
Fiber Optic Nut
15
Portion Control Knob
16
Automatic System Flush Button
17
Key Hole
18
BobKey
19
Optional: A/C Adapter Kit with U.S. Plug, Order Part
No. 3974-57.
International AC Adapter Plug Kit (UK, Europe
Australia) 3974-55
1
Scan For SureFlo Installation and
Maintenance Instructions.
2
3
17
4
5
1
6
7
12
9
8
11
10
19
18
14
16
13
15