Euro-Pro Shark G6118 Посібник користувача - Сторінка 3
Переглянути онлайн або завантажити pdf Посібник користувача для Залізо Euro-Pro Shark G6118. Euro-Pro Shark G6118 6 сторінок. 120v., 60hz., 1500 watts steam generator iron
TROUBLSHOOTING
Do not operate the steam generator with a damaged cord, plug or if the iron or any
other part of the system has been dropped or damaged. To avoid the risk of electric
shock, do not disassemble or attempt to repair the ironing system.
appliance to EURO-PRO Operating LLC (see Warranty) for examination and repair.
Incorrect re-assembly or repair can cause a risk of electric shock or injury to persons
when the ironing system is used.
PROBLEM
POSSIBLE CAUSES
1. On/Off button is not in the
"ON" position.
2. Steam generator has no more
No Steam Is
water.
Released
3. Unit is not plugged in.
Through The
4. Steam is not visible because
the temperature of the
Iron
soleplate is at maximum and
room temperature is high.
5. Generator is not fully heated.
The Soleplate
1. Temperature is set at
Remains Cold
"Minimum".
Drops Of Water
1. Soleplate temperature is too
low to iron with steam.
Leak From The
2. Generator is not fully heated.
Iron Soleplate
Dirty Or Yellow
1. Residue is water tank.
Steam Is
2. Not using demineralized/
Coming Out Of
distilled water.
The Iron
1. Gasket is broken because
Steam Leaking
boiler filler cap was closed too
From The Boiler
tightly or cap was opened
while tank was full of steam
Filler Cap
and gasket broke.
Return the
SOLUTIONS
1. Press the On/Off button to
the "ON" position.
2. Fill with water as per
instructions.
3. Make sure that the On/Off
button is in the "OFF"
position and plug the unit
into an electrical outlet.
4/5. The heating time for the
generator is approximately
11-13 minutes. Watch for
the steam ready light to go
off indicating that steam is
ready.
1. Turn the temperature
control dial to the desired
setting.
1. Turn the temperature
control dial to the marks
between 2 and 3 dots.
2. Wait for generator to be
fully heated.
1. Clean steam generator as
per instructions.
2. Use demineralized/ distilled
water after cleaning the
tank.
1. Order new boiler filler cap
from customer Service at
1 (800) 798-7398.
9
ADDITIONAL IMPORTANT SAFEGUARDS
Read all instructions before using the EURO-PRO Operating LLC Steam Generator
Iron and follow all the instructions and safeguards carefully.
CAUTION!
NEVER open the
boiler filling cap before ALL
the remaining steam has been
released from the steam
generator and the steam
generator has cooled. To
release the steam, press the
On/Off button to the "Off"
position and push the steam
button on the iron until no
more steam comes out of the
iron. Then open the boiler filler
cap slowly.
A WORD ON WATER
For best results we recommend using
100% demineralized/distilled water.
You can use regular tap water in your
steam generator, but should the water in
your area be hard water we strongly
recommend the use of 100%
demineralized/distilled water. This will
prolong the life of your generator and
reduce the frequency of required generator
cleaning, as well as the possibility of
staining due to accumulated impurities.
DO NOT USE WATER PROCESSED
THROUGH A HOME WATER
SOFTENING SYSTEM OR BOTTLED
MINERAL WATER.
DO NOT OVERFILL THE STEAM
GENERATOR
When empty, the steam generator can be
filled with 26 U.S. fl. oz. of demineralized/
distilled water. Do NOT overfill. Overfilling
the water tank can cause water drops to
come out of the steam holes. See filling
instructions on page 5.
DO NOT OVER TIGHTEN THE
BOILER FILLER CAP
To close the boiler filler cap, turn
clockwise until the point where you feel
friction – do NOT close too tightly. The
boiler filler cap has a gasket which can
be flattened and damaged if the cap is
closed too tightly. If the gasket is
damaged, steam may escape while the
steam generator is being used. If the
boiler filler cap is damaged and steam
is leaking, call EURO-PRO Operating
LLC customer service to purchase a
replacement boiler filler cap.
NEVER LEAVE THE HOT IRON
RESTING ON THE IRON REST
FOR LONG PERIODS OF TIME
The lifespan of your steam generator
will be reduced if the iron is left idle at
high temperatures for extended
periods of time. If the iron is not in use,
reduce the temperature to the lowest
temperature setting on the temperature
control thermostat, turn the steam
generator "Off" and remove the power
cord from the electrical power outlet.
WARRANTED FOR REGULAR
HOUSEHOLD USE
While the Steam Generator Iron is a
professional type ironing system; it is
intended for and warranted only for
normal household use. The iron and/or
steam generator should not be used
for more than fifteen (15) hours per
week in approximately three (3) hour
intervals.
2